Suitable for 300 ℃ high temperature material thickness measurement, range 2.0~ 100mm, diaMeter 14mm, minimum diaMeter 30mm, 5MHz Frequency to achieve accurate measurement.
Using 2.0MHz Frequency Probe, Measurement range 2.0~ 400.0mm, dedicated to the thickness detection of coarse crystal materials such as cast iron, the lower limit of pipe measurement Φ 30 * 4mm.
Suitable for material measurement with temperature less than 350 ℃, with 5.0MHz Frequency and lower limit of pipe measurement Φ 25 * 3mm, to meet the needs of accurate thickness detection in high temperature environment.
Using 5MHZ Frequency and 14mm diaMeter design, support 3.0~ 200mm steel material measurement, minimum pipe diaMeter 30mm, suitable for high temperature environment, temperature measurement range of 450 ℃, to ensure accurate thickness detection.
Using 7.5MHz High Frequency Probe, Measurement range 0.7~ 50mm, suitable for thin-walled and small arc surface workpieces, the lower limit of pipe measurement is Φ 25 * 1.2mm, strong adaptability.
Measurement range 0~ 10000μm, error +/- 3%, wear-resistant aluminum alloy Probe surface, braided cable high temperature resistance, split structure can extend cable length to achieve remote measurement, can read more than 180 data per minute.
Probe surface with wear-resistant aluminum alloy, braided cable to adapt to high temperature rough surface, resolution up to 0.1 μm, support split remote measurement, can store 2500 readings.
Adapted to 5500 and 9500 series Probe, using straight Probe design, providing stable connection and reliable data transmission, improving the efficiency of coating thickness measurement.
Measurement range 0~ 625μm, accuracy +/- 1%, waterproof sealing structure suitable for underwater measurement, constant pressure Probe to ensure measurement Stability.
Using 5MHZ Frequency and 14mm diaMeter design, support 450 ℃ high temperature environment measurement, Measurement range 3.0~ 200mm (steel), minimum pipe diaMeter 30mm, suitable for high temperature material thickness detection.
Detachable built-in Probe design, support one-handed operation, Measurement range 0~ 38mm, accuracy +/- 3%, minimum measurement surface 83 × 83mm, suitable for various surface Coating thickness measurement.
The 90 ° right angle Probe design is suitable for low headroom area measurement, the fully waterproof structure supports underwater operation, the Measurement accuracy is +/- (0.05 mils + 1%), and the stainless steel sealing Probe ensures durability.
Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.
Measurement principle using magnetic method, thickness range 0-3000μm, error +/- 3%, with split Probe structure, support single and continuous Measurement mode, equipped with RS-232C interface.
Using 5MHZ Frequency and 10mm diaMeter Probe, Measurement range 1.2-230 mm (steel), used at room temperature, suitable for thickness detection in different environmental conditions.