Haze Meter

The haze meter measures the intensity of transmitted and scattered light by illuminating a sample with a light source and calculates the haze value. It is used to assess the turbidity of transparent or translucent materials such as plastic films and glass, and to determine whether the material's transparency meets quality standards during inspections.
Selection
When selecting a haze meter, consider that the measurement range covers the haze range of the sample, the accuracy meets the requirements of testing standards, the operation interface is simple and easy to read, the instrument has good stability and is easy to calibrate, and it is compatible with the size and shape of existing samples.

Terms

Instruments

Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.

$ 11337.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor to achieve 0.01 unit haze resolution; Equipped with dynamic measurement function, real-time monitoring of environment changes to ensure data Reliability; Open measurement area supports vertical horizontal test.

$ 7464.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy to achieve High Accuracy Transmittance and haze measurement, Repeatability is less than 0.05, Support a variety of observation Illuminant and dynamic temperature monitoring.

$ 7464.00

Using 256-pixel dual-array CMOS image sensor and concave grating spectroscopy, the haze resolution reaches 0.01 units, supports dynamic measurement and open sample area, and adapts to the needs of different thickness sample testing.

$ 7464.00

Using 256-pixel dual-array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, and supports dynamic measurement and multiple observation Illuminants to ensure reliable data and adapt to different sample testing needs.

$ 7464.00

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

Using 256 pixel dual array CMOS sensor and concave grating spectroscopy, haze Repeatability is less than 0.05, support dynamic measurement and a variety of chroma indicators, adapt to vertical or horizontal testing.

$ 7464.00

The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the haze Repeatability is within 0.15, and the open sample compartment supports vertical horizontal testing to adapt to different thickness samples.

$ 961.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical and horizontal dual-mode testing, and a dynamic measurement system is equipped to ensure data Reliability.

$ 1977.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical horizontal testing, and a dynamic measurement system is equipped to monitor environment changes to ensure data Reliability.

$ 1977.00

The PD array Detector and Φ 8mm measurement aperture are used to meet the CIE V (lambda) 2 degree visual Response, and the open sample compartment supports vertical horizontal testing. Measurement time is about 1.5 seconds, and the haze resolution is 0.01 units.

$ 1655.00

Light spectrum LED Illuminant and Light spectrum Sensor, equipped with 14mm and 5mm dual measurement aperture, haze Repeatability ≤ 0.03, with open measurement area to support liquid and large size sample detection.

$ 1455.00