Basket Paint Grinding Machine

The basket-type paint grinder achieves pigment dispersion and particle refinement by rotating the basket to drive the grinding media at high speed, subjecting the material to shear and impact within a closed space. It is used for slurry preparation in industries such as paints and inks, ensuring product uniformity and stability.
Selection
Select the motor power based on the viscosity of the material, configure the grinding media type according to the fineness requirements, determine the basket capacity based on the production volume, choose the machine structure in combination with the site dimensions, and refer to the material's corrosion resistance to suit the production environment.

Terms

Standards

Instruments

The three-phase asynchronous motor is safe and spark-free, can handle high viscosity materials and support long-term continuous work, grinding basket volume 1.8L, speed range 0~ 3000rpm/min, to achieve efficient dispersion and refinement of grinding.

$ 3785.00

Set dispersion and sand grinding functions in one, complete two processes in a single container, speed range 130~ 3000rpm, grinding basket size Φ 80x60mm, high efficiency and easy to clean.

$ 1413.00

Using 1400rpm speed regulation and 1.5 liters effective volume sand grinding basket, rapid dispersion and grinding are achieved through tensile shear and Impact between sand and material, and the operation is simple.

$ 574.00

Rotation speed up to 3000rpm, fineness of grinding up to 10 microns or less, double-decked chilled down jacket design makes the conventional temperature rise less than 10 ℃, zirconia dial drive grinding medium to achieve efficient dispersion grinding.

$ 1063.00

The equipment can complete two processes of dispersion and grinding at the same time, Rotation speed 0-1500rpm, grinding capacity 30-100L, using zirconia grinding medium and chill down jacket design, temperature rise is small, easy to operate.

$ 5721.00

Rotation speed up to 3000rpm, fineness of grinding up to 10 microns or less, double-decked chilled down jacket design temperature rise less than 10 ℃, equipped with zirconia bead grinding medium to achieve efficient wet grinding, separation plate using whole CNC processing life is long.

$ 1124.00

The equipment adopts electric lifting and frequency conversion speed regulation, Rotation speed 0-3000 rpm, equipped with double-decked chilled down jacket and zirconia bead grinding medium to achieve efficient wet dispersion grinding, small temperature rise and easy operation.

$ 2655.00

Rotation speed up to 3000rpm, fineness of grinding up to 10 microns or less, equipped with double-decked chill down jacket temperature rise of less than 10 degrees, zirconia bead grinding medium and CNC separation plate design, easy to operate and clean.

$ 3814.00

Rotation speed 0-3000rpm, fineness of grinding can reach 10um or less, double-decked chill down jacket is used to control temperature rise less than 10 ℃, electric lifting operation is convenient, zirconia bead grinding medium to achieve efficient dispersion and ground synchronization.

$ 2676.00

Rotation speed up to 3000rpm, fineness of grinding generally up to 10um or less, liquid-liquid dispersion ground up to sub-micron or even nano level; double-decked chilled down jacket design, conventional temperature rise less than 10º, to ensure pRoduct Stability.

$ 2468.00

Rotation speed up to 3000rpm to achieve efficient grinding, fineness up to 10μm or less; double-decked chill down jacket design makes the operating temperature rise less than 10 ℃, to ensure material Stability; zirconia bead grinding medium, suitable for a variety of viscosity material processing.

$ 1124.00

Electric lifting design to achieve dispersed ground synchronization, maximum Rotation speed 3000rpm, fineness of grinding up to 10um or less, configuration double-decked chill down jacket temperature rise less than 10º, zirconia bead medium to ensure efficient grinding.

$ 3089.00

Rotation speed 3000rpm, using zirconia lever to drive the grinding medium high-speed collision friction, quickly reduce the material particle size. Equipped with double-decked chill down jacket, the conventional temperature rise is less than 10 ° C to ensure pRoduct Stability. Unique cavity design supports solvent circulation cleaning, easy operation and low maintenance cost.

$ 3502.00

Full explosion-proof design to ensure safe operation, the main motor Power 22kW, grinding range 0-1450 rpm, equipped with 20L grinding basket and custom PTFE grinding sleeve, wear-resistant heat dissipation fast, hydraulic lift Travel 1200mm.

$ 10562.00

The use of diamond sanding needles can flatten the surface of the grinding wheel, improve the utilization rate of abrasive wheels, and is equipped with a water supply system to support wet grinding and dry grinding. The size of abrasive wheels is about 250 × 30 × 32mm, and the Rotation speed is 1400rpm.

$ 1239.00

Articles

How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Flexibility of Elastic Coatings Tested by Cylindrical Mandrel Bend Tester
This article introduces a method for testing the flexibility of elastic coatings using a cylindrical mandrel bending tester. During the test, the coated test panel is bent around cylindrical mandrels of varying diameters to 180 degrees to observe whether the coating cracks or peels off.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.