Low Temperature Cooling Water Circulator

The low-temperature cooling water circulator compresses the refrigerant through a compressor to release heat, and then throttles it through an expansion valve to absorb heat, thereby cooling the circulating water. It is used for constant-temperature cooling of laboratory equipment, such as temperature control for rotary evaporators and reaction vessels.
Selection
When selecting, consider the required temperature range, cooling power and equipment compatibility, check the water pump flow and pressure parameters, pay attention to the corrosion resistance of the tank material, ensure the device dimensions fit the installation space, and verify the power supply voltage compatibility.

Terms

Standards

Instruments

Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.

$ 2287.00

With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.

$ 1146.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Temperature range room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, with low water level protection and alarm function.

$ 2061.00

Temperature control accuracy of +/- 0.05 ℃, support room temperature to 300 ℃ range of water and oil dual-use, equipped with high temperature centrifugal pump head 5 Meters, domestic circulation system to achieve uniform temperature field.

$ 825.00

Temperature range Room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, support water-oil dual-use medium; High temperature centrifugal pump head 5 Meters, to achieve uniform temperature field inside and outside circulation, built-in multiple Safety protection devices.

$ 1166.00

Temperature range covers -50 to 200 ° C, supports 200 ° C direct start cooling without damaging the Compressor; uses a heat-free centrifugal circulation pump and U-shaped return design to ensure Temperature Uniformity +/- 0.05 ° C; provides a variety of Safety protection such as low water level and temperature runaway alarm.

$ 2044.00

Using environmental refrigerant R134a, the cooling time is reduced by more than 40%, Temperature range -40~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, support multi-stage programming and independent temperature limit alarm, easy to operate and clean.

$ 3462.00

Adopt proportional refrigeration and PID control technology, support 30-stage program control, Temperature Fluctuation +/- 0.05K, with multiple safety protections such as water shortage protection and overheating and overflow, and the pump Flow rate reaches 12L/min.

$ 1519.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

Temperature range -20~ 100 ℃, accuracy +/- 0.02 ℃, equipped with over-temperature alarm and liquid level protection function, using imported Compressor noise low cooling fast, support multi-stage programmable and data processing interface.

$ 1953.00

Temperature range -10~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, low noise, fast cooling, with over-temperature alarm and liquid level protection function, support multi-stage programming and data processing interface.

$ 1756.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 1156.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 3586.00

It can precisely control the temperature in the range of room temperature to 300 ° C, Temperature Fluctuation +/- 0.05 ° C, equipped with high temperature centrifugal jet circulation pump, head 5 Meters, support the internal and external circulation system, and achieve a highly uniform temperature field.

$ 672.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Condensation test chamber simulates the impact of humid environments on coatings.