Horizontal Steam Sterilizer

A horizontal steam sterilizer creates a high-temperature and high-pressure environment inside a sealed chamber using saturated steam, causing microbial proteins to denature and become inactive. It is used for sterilizing laboratory glassware, culture media, and other items, ensuring aseptic operating conditions in fields such as healthcare and biology.
Selection
When selecting, consider matching the sterilization chamber volume with the processing capacity, ensure the material is corrosion-resistant, and pay attention to temperature uniformity and the integrity of safety devices. Confirm the working temperature range based on the types of items to be sterilized, determine the equipment footprint according to the site dimensions, and verify the power supply and steam source configuration requirements.

Terms

Standards

Instruments

Irreversible discoloration records the highest temperature, accuracy +/- 1 ° C to +/- 4 ° C, four-speed temperature monitoring range 104-121 ° C, oil-resistant, water-resistant and steam-resistant, instant Response without power supply.

$ 93.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

Adopting the principle of irreversible discoloration, the accuracy is +/- 1 ° C below 100 ° C, with 6 temperature grids from 65 ° C to 93 ° C, oil, water and steam resistance to ensure stable operation in harsh environments.

$ 93.00

Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.

$ 580.00

Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.

$ 490.00

Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.

$ 325.00

Adopt back heating horizontal forced convection technology, Temperature Fluctuation +/- 0.5 ℃, Temperature range RT + 10~ 200 ℃. Sensor fault alarm, over-temperature protection and independent temperature limit Control system ensure the safety and reliability of the experiment.

$ 377.00

Equipment supports vertical and horizontal combustion test, can set combustion and extinguishing time and repeability times, automatic stop test, Internal dimensions 305 * 355 * 610mm, suitable for a variety of organic materials.

$ 691.00

Adopt horizontal oscillation mode, Frequency 0-240rpm continuously adjustable, stable work and low noise, equipped with 340 * 250mm tray to meet the needs of a variety of experimental containers.

$ 199.00

Horizontal Vibration Technology, Vibration Frequency 45-200Hz Adjustable, Throwing plate diaMeter 300mm, can handle multiple samples and automatically complete the polishing process.

$ 5834.00

Rated load 1000N, Travel 100mm, manual operation is stable, can adapt to a variety of Force Gauge, suitable for tension and compression load and plug force test, horizontal structure for desktop installation.

$ 256.00

Horizontal forced convection technology to ensure Temperature uniformity, temperature control accuracy of 0.1 ℃, equipped with High Accuracy Platinum Resistance Sensor and 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.

$ 422.00

Horizontal press measurement with physical positioning observation window, Repeatability accuracy up to dE * ab ≤ 0.02, support 5 measurement diaMeters and over 30 Measurement paraMeters, equipped with full band equalization LED Illuminant, Measurement time of about 1 second.

$ 1364.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical and horizontal dual-mode testing, and a dynamic measurement system is equipped to ensure data Reliability.

$ 1977.00

The PD array Detector is used to achieve 0.01 unit haze resolution, the open sample compartment supports vertical horizontal testing, and a dynamic measurement system is equipped to monitor environment changes to ensure data Reliability.

$ 1977.00