Solar Panel Transmittance Tester

The solar sheet transmittance tester measures the transmittance data by irradiating the sample with a light source and calculating the ratio of transmitted light intensity to incident light intensity. It is used to evaluate the light transmission performance of materials and is commonly applied in quality control for products such as plastics, glass, and films.

Instruments

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

Measurement accuracy better than +/- 2% with high definition color screen progress bar, data locking and real-time dynamic Adjustment.

$ 149.00

Simultaneous measurement of infrared, ultraviolet blocking rate and visible light transmittance, resolution up to 0.1%, accuracy better than +/- 2%. Using high definition color screen progress bar visual display, with data locking and real-time dynamic Adjustment to ensure accurate measurement.

$ 122.00

Split design with super magnetic automatic suction, can be directly tested on the installed film Glass, using 1400nm Infrared source and 365nm UV light source, measurement accuracy of +/- 2%, with laser alignment function to ensure measurement accuracy.

$ 390.00

Fully pneumatic design ensures stable operation, adjustable spray gun settings for precise atomization and film thickness control, and magnetic panel supports multiple substrate tests.

$ 59126.00

Glass transmittance measurement is facilitated by split dual-machine design, integrated UV-IR-VIS 3-in-1 test function, equipped with laser alignment to ensure measurement accuracy +/- 2%, and supports built-in lithium battery power supply.

$ 357.00

The three-in-one optical path measures the transmittance of three wavelengths at one time, the test aperture is 1mm to adapt to small-sized materials, and the parallel light design ensures stable measurement of thick materials, with an accuracy of +/- 2% and a resolution of 0.1%.

$ 361.00

Measurable six paraMeters including UV barrier rate, visible light transmittance, infrared 950nm, 1400nm, Full IR and SHGC, using parallel light design, test accuracy +/- 2%, suitable for large Film thickness Glass, with real-time dynamic self-calibrating function.

$ 364.00

Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.

$ 361.00

The minimum test aperture is 0.5mm, and the three Illuminants share a test hole. Three transmittance data of 550nm, 850nm and 940nm can be obtained for one hole. Real-time dynamic self-Adjustment, Test accuracy +/- 2%.

$ 538.00

It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.

$ 341.00

Parallel light path design can measure 100mm thickness material, accuracy +/- 1%, resolution of 0.001%, support field and fixed station two Measurement mode, suitable for a variety of Optical inspection material detection.

$ 390.00

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Utilizing a 360-780nm composite full-spectrum LED light source, equipped with a 256-pixel CMOS detector and a concave grating, it achieves spectral acquisition at 10nm intervals, supporting micro-transmittance measurements and a variety of optical index tests.

$ 6851.00

Using 3-in-1 optical path design, one hole can simultaneously measure three wavelengths transmittance. Equipped with 1mm test aperture and Automatic calibration function, support 850nm/940nm infrared and 550nm visible light measurement, accuracy of +/- 2%.

$ 373.00

Articles

Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Haze and transmittance integrated machine measures the quality of functional films.
This article introduces how an integrated haze and transmittance meter measures the quality of functional films. Haze refers to the degree to which a material scatters light, while transmittance reflects its overall ability to transmit light.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.