Methyl Bromide Detector

A bromomethane detector captures changes in the concentration of bromomethane gas in the air through a sensor, generating an electrical signal that is converted into a reading. It is used for environmental monitoring in fumigation sites, warehouses, and other locations to prevent personnel poisoning and environmental pollution.
Selection
When selecting, focus on the detection range covering the concentration in the usage scenario, sensor lifespan and calibration cycle, explosion-proof rating matching the on-site environment, determine between portable or fixed types based on needs, and check the response time and data logging functions.

Instruments

Electrochemical sensor, detection range 0-400ppm, accuracy +/- 2% F. S, with Intrinsic Safety (IS) design and automatic Zero tracking function, support a variety of signal output and remote monitoring, strong anti-interference ability.

$ 764.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With Intrinsic Safety (IS) design and IP66 Protection Rating, it supports multiple signal output and remote monitoring functions, suitable for harsh industrial environments.

$ 638.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and IP66 Protection Rating, support a variety of signal output and remote monitoring functions.

$ 638.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and automatic Zero tracking function, support a variety of signal output and remote monitoring, strong anti-interference ability.

$ 764.00

Using infrared NDIR detection principle, range 0~ 2% Vol, resolution up to 0.001, Response Time ≤ 30 seconds, with flameproof structure and 10-year Sensor life, support a variety of signal output and remote monitoring.

$ 977.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switching signal output, can be operated by remote control without opening the lid, with local sound and light alarm and remote alarm function.

$ 912.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.

$ 654.00

Adopt PID photoion detection principle, range 0-50ppm, resolution up to 0.01, Response Time ≤ 30 seconds. With flameproof structure, support 4-20mA, RS485 and wireless signal output, can be operated by remote control without opening the lid, adapt to -20~ 50 ℃ working environment.

$ 1235.00

Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support 4-20mA, RS485 and switch output, can be operated by remote control without opening the lid, with sound and light alarm and a variety of wireless transmission methods.

$ 912.00

Using infrared NDIR detection principle, range 0-50g/m3, accuracy ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA and RS485 output, with explosion-proof design and remote alarm function.

$ 977.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.

$ 99.00