Liquid Yellowing Resistance Test Chamber

The liquid yellowing resistance test chamber simulates ultraviolet sunlight exposure and a constant temperature environment to assess the color stability of liquid materials under light. It is used for quality control in industries such as coatings and inks to evaluate the product's resistance to yellowing.
Selection
When selecting, focus on the matching between the UV wavelength and the sample. The temperature uniformity within the chamber should be within ±2℃, and the capacity should be determined based on the sample quantity. The operation interface should be simple and intuitive, featuring timing and automatic shutdown functions. The materials should be corrosion-resistant and easy to clean.

Terms

Standards

Instruments

Using 300W solar bulbs and hot air circulation heating, Temperature range RT +~ 120 ℃, can accurately control the test conditions, determination of material under light yellowing resistance performance, suitable for a variety of shoe material testing.

$ 1719.00

The 300W OSRAM bulb provides 365-400nm wavelength UV, Temperature Uniformity +/- 1 ℃, can be tested for yellowing resistance and aging at the same time, and the turntable Rotation speed 10 +/- 2rpm ensures uniform sample irradiation.

$ 1143.00

300W yellowing resistant bulb provides 365-400nm wavelength ultraviolet, Temperature Uniformity +/- 1 ℃, can simulate the atmospheric environment accelerated testing, one machine multi-purpose support aging Oven function.

$ 1272.00

Suitable for laboratory sampling test, high corrosion resistance, can measure a variety of material density, with sampling test type for liquid special anti-corrosion accessories.

$ 123.00

Supports more than 30 chroma indicators, Measurement accuracy ≤ E * ab ≤ 0.01, single measurement only takes 1.5 seconds, minimum liquid addition is as low as 1ml, equipped with thermostatic sample tank and 7 inch Touchscreen.

$ 4075.00

The equipment is designed according to the international coating stain resistance experimental method, the water Tank volume is 5L, the inner diaMeter of the flow pipe is 8mm, and the time control range is 0~ 99h99s. It is suitable for the stain resistance test of building exterior coatings.

$ 412.00

4-Terminal Resistance Measuring method is used to eliminate the influence of wire resistance. Test speed is up to 6 times/sec. Measurement current is less than 100mA to prevent temperature drift and ensure Precision and Stability.

$ 146.00

Impedance of PHY Glass film less than 500MΩ, with porous PTFE liquid complex and silver ion trap reference system, support 0~ 130 ℃ wide temperature measurement, Response is fast and stain resistance is strong.

$ 264.00

Using stain removal rate evaluation method, scruf speed 37cpm, load 1000g, can accurately adjust the liquid Flow rate, by measuring the reflection coefficient changes to evaluate the stain resistance of coatings.

$ 1103.00

Using 2-wire method and 3-wire method measurement, Ground Voltage Measurement range 0~ 200V, Ground Resistance Measurement range 0~ 1999 Ω, Response Time about 5 seconds, with continuous measurement and overload protection function.

$ 159.00

Temperature range -20~ 150 ℃ and humidity control 30~ 98% R.H., using PID control and solid state relay to ensure stability, multi-layer Glass observation window frost-proof design, support a variety of safety protection functions.

$ 6189.00

Adopt high temperature fan and special air duct to ensure temperature uniformity, equipped with low speed turntable; Temperature range RT + 10~ 200 ℃, uniformity +/- 2 ℃, support 3-100 times/h ventilation volume adjustment.

$ 6044.00

Adopt high temperature and low noise motor and multi-leaf centrifugal wind turbine, Temperature Uniformity +/- 2 ℃, equipped with low speed turntable and hot air circulation system to ensure stable and uniform temperature in the working room.

$ 8045.00

The use of high temperature fan and special air duct to achieve uniform heating, equipped with low-speed turntable to ensure uniform heating of the sample, Temperature Fluctuation control within +/- 0.5 ℃, ventilation can be adjusted within the range of 3-100 times/hour.

$ 6560.00

Temperature range -30~ 150 ℃ and Temperature Uniformity ≤ +/- 2 ℃, using multi-layer conductive film observation window anti-frost design, equipped with independent over-temperature protector and solid state relay control to ensure stable operation.

$ 7948.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.