High Temperature Optical ThermoMeter

High-temperature optical thermometers detect the infrared energy emitted by an object's thermal radiation and convert it into temperature readings. They are used for non-contact measurements in high-temperature scenarios such as furnaces and metal processing, avoiding damage caused by direct contact.
Selection
When selecting, pay attention to whether the temperature measurement range covers the requirements, ensure the response time matches the change rate of the measured object, consider the emissivity setting function and environmental anti-interference capability, and confirm the suitability of the optical resolution and installation interface.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

The equipment temperature range -50~ 750 ℃, object distance ratio 12:1, Response Time 500ms, with non-contact measurement, High Accuracy and Fast Response characteristics, suitable for a variety of industrial scenarios.

$ 95.00

With CAL Check ™ boot Self-check function, temperature measurement accuracy of +/- 0.2 ℃, using penetrating AISI 316 stainless steel Probe, IP65 waterproof, suitable for semi-solid and frozen material temperature measurement.

$ 199.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Using penetrating AISI 316 stainless steel Probe, temperature range -50.0~ 220 ℃, accuracy +/- 0.2 ℃, with boot Self-check function, easy to clean and suitable for semi-solid and frozen materials.

$ 262.00

With penetrating AISI 316 stainless steel Probe, easy to clean and insert semi-solid pRoducts. With CAL Check ™ boot self-check function, temperature accuracy of +/- 0.2 ℃, Measurement range covering -50.0~ 220 ℃.

$ 211.00

Imported high-luminance Illuminant and narrow-band filter system, Optical inspection stability ≤ 0.002A/20min, measurement range 0.01~ 1.00mg/L, support users to calibrate Linear dispersion, good corrosion resistance of the host case.

$ 499.00

Imported high-luminance Illuminant and narrowband filter system, Optical inspection stability ≤ 0.002A/20min, measurement range 0.01~ 0.50mg/L, equipped with large-screen LCD Chinese display, support long-term data storage and user self-calibration.

$ 499.00

Imported high-luminance Illuminant and stable Optical inspection system, with repeatability ≤ 2%, intrinsic error +/- 3% (F. S), equipped with large-screen LCD and power-off data recording function.

$ 533.00

The temperature measurement range covers -18 to 1350 ° C, the object distance ratio is 20:1, and the Response Time is 500ms. It can safely and accurately measure the surface temperature of difficult-to-contact objects, and the structure is compact and easy to operate.

$ 171.00

Imported high-luminance Illuminant, Optical inspection stability ≤ 0.002A/20min, equipped with narrow-band filter system anti-interference, large-screen Chinese display, support users to calibrate Linear dispersion, host anti-corrosion.

$ 499.00

Optical inspection system with dual beam of light feedback compensates for Illuminant fluctuation in real time, Light spectrum reflectance Repeatability Standard Deviation is less than 0.1%, and the inter-device difference Delta E * ab is as high as 0.08, which can accurately measure fluorescent materials without UV correction.

$ 27183.00

Using diffuse transmission optical path design, optical density Measurement range 0.00-6 OD, light transmitance accuracy +/- 2%, can simultaneously measure light transmitance, absolute optical density, relative optical density and Dot area ratio.

$ 673.00

Foldable stainless steel probe design, temperature range -49.9~ 49.9 ℃, Accuracy up to +/- 0.5 ℃, equipped with large LCD display and Fahrenheit switching function, easy to high temperature liquid safety measurement.

$ 318.00

Adopt cold Illuminant narrow-band interference Optical inspection system, Optical inspection stability is less than 0.002A/20min, support room temperature to 180 ℃ stepless temperature control, anti-chlorine interference up to 2000mg/L, batch processing of 20 water samples, easy to operate without changing pipes.

$ 1564.00

Temperature measurement range 200~ 1850 ℃, object distance ratio 80:1, Response wavelength 900~ 1700nm, support Data storage and USB connection, suitable for long-distance accurate measurement.

$ 263.00