Two-channel split design supports multi-point centralized control, with 4-20mA signal input and two-level alarm settings, microprocessor to ensure accurate monitoring, relay output can drive external equipment linkage, Operating temperature range -10~ 50 ℃.
Electrochemical sensor, formaldehyde detection range 0-20ppm, resolution 0.1ppm, with sound, light, vibration triple alarm, IP65 Protection Rating, built-in 1500mAh lithium battery can work continuously for 8 hours.
Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.
Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.
Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.
Support 4-20mA signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching and sound and light alarm functions, operating temperature 0-40 ℃, suitable for a variety of Gas detection scenarios.
Electrochemical sensor, Response Time less than 30 seconds, Measurement range 0~ 10ppm, with explosion-proof structure and 4-20mA standard signal output.
Explosion-proof structure design, Response Time is less than 30 seconds, with 4-20mA standard signal output, can detect a variety of gas concentrations and set high and low alarm points to ensure industrial environment safety monitoring.
Maximum 4 kinds of gas simultaneous detection, integrated temperature and Humidity monitoring, with sound and light alarm function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.
Using Industrial Sensor, Response Time less than 30 seconds, accuracy +/- 3% FS, shell explosion-proof structure, 4-20mA standard signal output, can detect a variety of gas concentrations and have sound and light alarm function.
Using industrial grade Sensor, Response Time is less than 30 seconds, accuracy +/- 3% FS, with explosion-proof and explosion-proof shell design, support 4-20mA and RS485 output, adapt to -10~ 40 ℃ working environment, ensure reliable monitoring of various gas concentrations.
Support 4-20mA and RS485 signal input, compatible with two-wire and three-wire devices, provide 6 passive switching control ports, with two-level alarm setting and alarm record query function, temperature operation range 0-40 ℃.
Electrochemical sensor, Response Time less than 30 seconds, Measurement accuracy +/- 3% FS, 4-20mA standard signal output and passive relay control port, suitable for a variety of Gas detection needs.
Support 32 Detector access, using 4-20mA signal transmission, with two-level alarm settings and 20,000 records Storage capacity, through the relay drive peripherals to ensure safety protection.
Support 8 channels of 4-20mA signal input, can store 20,000 alarm records, with two-level alarm settings and relay output, suitable for multi-point centralized control to prevent explosions and fire accidents.