Alkali Concentration Meter

The alkali concentration meter calculates the alkali content by measuring the electrical conductivity of a solution or through acid-base neutralization reactions. It is used to monitor changes in alkali concentration in industrial processes, commonly applied in process control and quality inspection in industries such as papermaking and textiles.
Selection
When selecting, consider matching the measurement range to process requirements, pay attention to temperature compensation features to adapt to field environments, verify material corrosion resistance, confirm the simplicity of calibration methods, and evaluate the response speed's compatibility with the process.

Terms

Standards

Instruments

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, surrounded by 316L stainless steel material comprehensive corrosion resistance.

$ 643.00

Microcrystalline Glass panel is resistant to strong acid and alkali, low expansion coefficient to ensure no deformation at high temperature; Operating temperature 450 ℃, ceramic fiber insulation material is lightweight and efficient, and 316L stainless steel around is corrosion resistant.

$ 612.00

Using high temperature non-alkali fiberglass insulation material, resistance wire sealing in the insulating layer, large heating area, fast heating, good thermal insulation effect, the highest temperature 380 ℃, power 4000W, no open flame design, not easy to bruise Glass ware.

$ 699.00

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, 316L stainless steel material comprehensive anti-corrosion, ceramic fiber insulation material lightweight and efficient.

$ 403.00

Using 8.0mmPP polypropylene (PP) plate welding, strong acid and alkali corrosion resistance, surface wind speed 0.4-0 m/sec, noise control below 65dB, the baffle can be disassembled and assembled with repeability to ensure uniform gas discharge.

$ 2187.00

Adopt 8mm thickness PVC reinforced rigid plastic plate shell, sulfur dioxide concentration 10~ 30ppm adjustable, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, Temperature Uniformity ≤ +/- 2 ℃.

$ 15581.00

The PHY Glass membrane is used to withstand strong acid and alkali corrosion, and the membrane Impedance is less than 500MΩ to ensure the measurement Stability; the porous PTFE liquid complex and 3M KCl gel electrolysis solution are designed to improve the anti-pollution performance, suitable for 0-130 ℃ high temperature environment.

$ 296.00

8Mm thick PVC reinforced rigid plastic plate box, sulfur dioxide concentration adjustment range of 600~ 10000ppm, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, temperature control accuracy +/- 0.5 ℃.

$ 15823.00

Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.

$ 11079.00

The diazotization method is used to react with nitrite to generate pink color. Measurement range is 0~ 600μg/L, and 100 tests are provided. It is suitable for a variety of Photometers to ensure accurate and reliable concentration determination.

$ 186.00

Volume 12 liters, the concentration of 5% -35%, equipped with manual speed regulation and digital Rotation speed display function, stainless steel material and new sealing technology to prevent leakage.

$ 3946.00

Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.

$ 215.00

Measurement range 0.0~ 12.5 ppm, accuracy +/- 0.1 ppm +/- 5% of reading, fast and easy Ion concentration detection based on DPD method.

$ 215.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ElectRode, Measurement accuracy +/- 0.5% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Key points for measuring the pH of water-based ink with a pH meter
This article introduces the key steps for measuring the acidity or alkalinity of water-based inks using a pH meter.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.