Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.
With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.
Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, using proportional refrigeration technology and PID control, support internal and external circulation and programmed operation, with low liquid level and over temperature protection, suitable for a variety of application environments.
With heating and cooling functions, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support 10-stage program control and external communication, pump Flow rate 12L/min, suitable for internal and external circulation applications.
Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.
Adopt proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30 program settings, equipped with maintenance-free pressure pump and multiple Safety protection system, working noise is less than 45 decibels.
Adopt proportional refrigeration and PID control technology, support 30-stage program control, Temperature Fluctuation +/- 0.05K, with multiple safety protections such as water shortage protection and overheating and overflow, and the pump Flow rate reaches 12L/min.
Temperature range room temperature to 300 ℃, Temperature Fluctuation +/- 0.05 ℃, the use of non-heat centrifugal circulation pump to avoid their own heat impact temperature field, with low water level protection and alarm function.
Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.
Temperature range -5~ 95 ℃, accuracy +/- 0.05 ℃, Tank volume 15L, pump flow 6L/min, providing uniform and constant temperature field source, suitable for a variety of test needs.
Temperature range -40~ 95 ℃, temperature accuracy +/- 0.1 ℃, Tank volume 15L, providing uniform and constant temperature field source, suitable for a variety of test needs.
Temperature range -40~ 95 ℃, temperature control accuracy +/- 0.1 ℃, Tank volume 7.5L, circulating pump flow 6L/min, providing a uniform and constant temperature environment.
With proportional refrigeration and PID control technology, temperature control accuracy of 0.05K, support 30-stage program control. Adopt maintenance-free pressure pump, maximum Flow rate 22L/min, integrated multiple Safety protection system.
Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.
Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.