Water Salinity Meter

A water quality salinity meter measures the concentration of dissolved salt ions in water through conductivity. It uses electrodes to detect the electrical conductivity of the solution and converts it into a salinity value. It is used to monitor the salt content in seawater, aquaculture water, and industrial circulating water, ensuring the suitability of the water body.
Selection
When selecting, consider that the measurement range should cover the actual salinity of the water body, the accuracy should meet monitoring requirements, the electrode material should be corrosion-resistant, it should have temperature compensation functionality, the calibration method should be simple, the protection rating should suit the usage environment, and the data output interface should be compatible with recording equipment.

Terms

Instruments

Conductivity Detector EC measurement, salinity Measurement range 0.0~ 70.0ppt, accuracy +/- 1~ 2ppt. With waterproof design, automatic temperature compensation, unique Graphite electRode anti-oxidation and Repeatability, support a variety of unit display.

$ 252.00

With 5 measurement functions, support 1 to 5 point Conductivity Detector calibrating and automatic temperature compensation, can customize 13 paraMeters, equipped with 500 data storage and USB Communication interface, suitable for a variety of water quality paraMeters accurate measurement.

$ 667.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

Simultaneous measurement of conductivity, resistivity, TDS, salinity and temperature, support automatic temperature compensation and ElectRode diagnosis, Data storage 450 groups, with IP54 dustproof and waterproof rating, Measurement accuracy up to +/- 1.0% FS.

$ 514.00

With conductivity, TDS, salinity, resistivity four measurement functions, Measurement accuracy of 0.5% F. S, support 1 to 5 point calibrating and automatic temperature compensation, built-in 500 data storage and USB Communication interface to ensure full range accurate measurement.

$ 435.00

Supports dual paraMeter measurement of conductivity salinity, Measurement accuracy up to 0.5% F. S, with automatic temperature compensation and ElectRode diagnostic functions, can store 500 sets of data and comply with GLP specifications.

$ 323.00

High performance Polarographic Sensor, Measurement range 0.00-45 mg/L, with automatic temperature compensation and salinity compensation, support height compensation up to 4000 Meters, suitable for on-site fast measurement.

$ 1237.00

Measurement range salinity 0.0~ 28.0%, temperature 10~ 100 ℃, resolution 0.1% Brix, only 0.3mL sample volume, 3 seconds fast results, portable design weight 100g.

$ 198.00

Equipped with 7-inch TFT display, support conductivity, TDS, salinity, resistivity and Conductivity Detector ash 5 kinds of paraMeter measurement, Measurement accuracy of 0.5% F.S, automatic temperature compensation and 1000 groups Data storage function.

$ 593.00

Equipped with 7-inch TFT display, support conductivity, TDS, salinity and other 5 paraMeter measurement, Measurement accuracy of 0.5% F.S, with 1000 data storage and automatic temperature compensation function.

$ 677.00

With 7-inch TFT display and 1000 data storage, it supports Multi-ParaMeter measurement such as conductivity, TDS, salinity, etc., with an accuracy of 0.5% F.S., automatic temperature compensation and calibrated reminder function to ensure measurement Reliability.

$ 566.00

Platinum Sensor ensures fast and stable measurement, supports 1-3 point calibrate and 0.1-1 adjustable TDS conversion factor, with automatic temperature compensation and end point locking function, Measurement range covers 0-20mS/cm conductivity and 0-10ppt salinity.

$ 165.00

Measurement accuracy of 0.5% and automatic temperature compensation, 1 to 5 point calibrated and 500 data storage, ElectRode constant selection and salinity Measurement mode.

$ 435.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Non-contact Sensor with long life and two Measurement ranges (100 to 55000 μS/cm). The enclosure is made of Acetal Resin, which is resistant to seawater corrosion and supports monthly on-site calibrating for accuracy, with a maximum operating depth of 70 Meters.

$ 1719.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.