Solution Interfacial Tension Meter

The surface tension meter evaluates liquid properties by measuring the intermolecular forces on the liquid surface, based on the principle of the tendency of liquid surfaces to contract. It is used to test the wettability and stability of liquids such as coatings and inks, and to control process quality in the printing and plastics industries.
Selection
When selecting a solution surface tension meter, consider the measurement range and accuracy to match sample types such as high-viscosity liquids. Focus on the instrument’s ease of operation and maintenance requirements to ensure compatibility with the laboratory environment. Refer to practical application scenarios, such as rapid detection or long-term monitoring, to choose the appropriate model.

Terms

Standards

Instruments

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Equipped with quartz glass, suitable for strong acid and alkali solution testing, Measurement range 0-200mN/m, Accuracy 0.01mN/m, automatic zero adjustment, peak holding and result calculation, repeatability error is not greater than +/- 0.2%.

$ 977.00

Adopt electromagnetic force closed-loop measurement system, accuracy +/- 0.02mN/m, support 0-200mN/m range measurement, with automatic lifting and temperature detection functions, can test high viscosity liquids and dynamic surface tension changes.

$ 4458.00

Measurement range 0-200mN/m, resolution 0.01mN/m, with standard weight and standard material double calibrated, 32-bit ARM control to ensure operation accuracy, automatic stop and average function to improve operation efficiency.

$ 1332.00

The manual lifting platform is equipped with fast fine-tuning dual gear, supports platinum plate method and ring method dual Measurement mode, Measurement range 0-400mN/m, error is only +/- 0.1mN/m, can be connected to the computer to display the tension change in real time Linear dispersion.

$ 1531.00

Measurement range 0~ 180mN/m, accuracy 0.1mN/m, pure mechanical structure design, durable and easy to operate, suitable for teaching and laboratory use.

$ 961.00

Adopt ring test method, support standard weight and standard medium double calibration, Measurement range 0-200mN/m, accuracy +/- 1% FS, with automatic stop and average function, Repeatability is good.

$ 1526.00

Measurement range 0-500.0mN/m, accuracy 0.01mN/m, equipped with quartz glass strong acid and alkali resistance, automatic zero to maintain peak value, automatic calculation of Correction factor and average value, repeatability error is not greater than +/- 0.2%.

$ 1429.00

Measurement range 0~ 200mN/m, standard error +/- 0.03mN/m, support real-time Linear dispersion display and thermostatic control, easy and reliable operation.

$ 2207.00

The built-in 15ml test solution can be used for more than 100 times, the pen tip is designed to reduce liquid volatilization, in line with ASTM D2578 and TAPPI T698 international standards, the valid period is 6-8 months.

$ 98.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Measurement range 0-200mN/m, resolution 0.01mN/m, Automatic Correction factor calculation, Accurate test and Good Data Repeatability, Equipped with quartz glass to adapt to strong acid and alkali environment.

$ 2187.00

General ion standard solution with concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily calibrating needs.

$ 135.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Built-in 15ml test solution can be used more than 100 times, pen design to reduce liquid volatilization, in line with ASTM D2578 standard, valid period of 6 months, suitable for a variety of materials surface tension accurate test.

$ 99.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.
Application of Coating Machines in the Fabrication of Functional Layers for Perovskite Solar Cells
This article introduces the application of coating machines in the preparation of functional layers for perovskite solar cells. The performance of perovskite cells depends on the uniformity and quality of thin films, such as the electron transport layer and the light-absorbing layer, which are primarily prepared through solution-based coating methods.