Penetration Coating Thickness Gauge

The pen-type coating thickness gauge operates based on the principles of magnetic induction or eddy currents. When the probe contacts the coating, it generates an electromagnetic field, allowing the thickness of the coating to be measured based on the differences in the substrate material. It is commonly used for on-site rapid detection of the thickness of coatings such as paint and plating on metal substrates, and is frequently applied in fields like steel structures and automotive maintenance.
Selection
When selecting, confirm the substrate type (magnetic/non-magnetic) to match the probe principle; choose the measurement range based on the coating thickness range; consider the probe shape to adapt to curved surface measurements; require calibration for substrates and temperature compensation functions; portable design suitable for field operations, with battery life meeting testing needs.

Terms

Instruments

With coating penetration measurement capability, resolution up to 0.01mm, Measurement range 0.65-400 mm, support Probe automatic identification and zero calibrate, provide standard and MIN Minimum two Measurement modes.

$ 1351.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range of 3.0-600 mm with 2MHz Frequency and 22mm diaMeter design, high penetration capability, suitable for thickness detection of a variety of good conductor materials.

$ 211.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Echo-echo technology implementation of 0.15mm ultra-thin part measurement, resolution of 0.001mm, can penetrate 0.5mm coating measurement substrate Film thickness, support sound speed calibrated and difference mode settings.

$ 1655.00

Equipped with emission-echo and echo-echo two thickness measurement modes, can penetrate the coating measurement substrate thickness; Measurement range 0.65~ 600mm, accuracy +/- 0.05mm; Support Probe automatic identification and zero point calibrating.

$ 506.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement range 0-1000N penetration resistance, detection depth of 30 cm can be extended to 1.5 Meters, without the ring knife method can quickly obtain dry density data, complete the detection within 10 minutes.

$ 419.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Support 0 °, 10 °, 30 ° multi-angle test, equipped with 250mL liquid discharge funnel and 500mL measuringflask, can meet the needs of sanitary napkins and diapers at the same time, such as slippery penetration, re-penetration and other penetration performance measurement.

$ 603.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.