Non-stick tire time

The non-stick tire time measures the surface drying performance of road marking coatings. A standard non-stick tire time tester is gently pressed onto the wet film, and the time until the tire no longer picks up the coating is recorded. This is used to control the time for opening traffic after construction, preventing premature traffic flow from causing damage or contamination of the markings.
Selection
Consider environmental temperature and humidity, type of coating, and thickness when selecting. High temperatures and low humidity shorten the time, while thick films require extended measurement. Solvent-based coatings dry faster than water-based ones. In actual construction, determine a reasonable time range through on-site testing. Refer to standard specifications to match local climatic conditions.

Terms

Standards

Instruments

The instrument uses 241 +/- 6mm tire uniform rolling detection, wet film thickness 200um +/- 20um, every 30 seconds, repeability test, accurate determination of non-stick tire drying time, suitable for marking Coating quality control.

$ 231.00

The tire size of the instrument is Φ 241 +/- 6mm, weight 15.8 +/- 0.2kg, dedicated to marking Coating drying time test, easy to operate, accurate and reliable results.

$ 196.00

6-Channel design supports multi-directional temperature monitoring, can work for 60 minutes in a 500 ° C environment, using nano-aerospace environmentally friendly heat insulation materials, K-type Thermocouple ensures +/- 0.3 ° C High Accuracy measurement, effectively solving color difference and curing problems.

$ 1451.00

Suitable for non-aqueous titration ElectRode supplementary reference filling, specification 250ml, provides stable reference potential, supports a variety of ion composite ElectRode applications, to ensure Measurement accuracy.

$ 99.00

Using 200g weight and 1cm ² bottom area design, in line with GB/T 1728 standard, through the filter paper test method to accurately determine the film surface drying and practical drying time, easy to operate, reliable results.

$ 114.00

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

The instrument is designed with a heavy hammer structure, with a weight mass of 6600g +/- 33g, which is suitable for the bending performance test of reflective film. It is simple to operate and safe and reliable to measure, and meets the requirements of national standards.

$ 522.00

Using 45/0 ring lighting and concave grating spectroscopy technology, the measurement diaMeter is Φ 20mm, the non-contact measurement distance is 7.5mm, and the chromatic value Repeatability is within 0.03. Color difference formula and chroma index analysis are supported.

$ 8109.00

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Adopt 45/0 structure, measurement Repeatability dE * ab ≤ 0.02, Inter-instrument Agreement dE * ab ≤ 0.25, support non-contact detection, waterproof and dustproof IP66, multiple communication interfaces, LED Illuminant long life.

$ 3946.00

Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.

$ 509.00

D/8 illumination observation conditions, measurement time 20ms, 0.5mm distance from the sample non-contact measurement, built-in black and white calibrate and ETC real-time calibrate technology to ensure high repeability and accuracy.

$ 11583.00

Adopt 45/0 ° ring illumination and concave grating spectroscopy, measurement wavelength 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination, support a variety of Measurement modes and camera positioning.

$ 8109.00

The non-contact grating optocoupler Sensor is used to automatically collect data, with a nominal kinetic energy of 2.207J, supports automatic calculation of intensity and voice broadcast, and has a built-in steel anvil calibration function to improve detection efficiency and accuracy.

$ 369.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
Gel Time Tester Evaluates the Curing Speed of Unsaturated Resin at Room Temperature
This article introduces how a gel time tester evaluates the curing speed of unsaturated resins at room temperature.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Hall flowmeter measures the flowability of spray powder
This article introduces how a Hall flowmeter measures the flowability of spray powder. It uses a standard funnel to measure the time required for a certain mass of powder to flow out under gravity—the shorter the time, the better the flowability.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.