High and low temperature cold storage

High and low temperature cold storage controls the internal temperature through a refrigeration system to simulate extreme temperature environments. It is used for material weathering tests, product stability verification, and storage condition evaluation. In industries such as coatings and plastics, it is used to examine the performance changes of products under specific temperatures.
Selection
When selecting a high-low temperature cold storage, considerations should include the temperature range and fluctuation, insulation performance of the storage body, matching of the refrigeration method with usage requirements, completeness of safety protection devices, energy consumption, and space utilization. The specifications should be determined based on the actual size of the test samples and the required rate of temperature change, with attention paid to the long-term operational stability of the equipment.

Terms

Standards

Instruments

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

Adopt proportional refrigeration technology and high temperature direct drop technology, temperature fluctuation +/- 0.1 ℃, pump maximum Flow rate 22L/min, support short time idling and low liquid level protection, long service life.

$ 2136.00

Temperature control accuracy of +/- 0.3 ℃, support for the installation of a variety of folding fixture, suitable for different materials in low temperature environment folding performance test.

$ 6205.00

Adopting independent control design of hot and cold box, the temperature conversion time does not exceed 15 seconds, and the recovery time is within 5 minutes. Equipped with safety interlock function and standard lead hole tube, it enhances test efficiency and operation safety.

$ 29120.00

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

Using stainless steel inner and outer box material, Temperature control accuracy of +/- 0.3 ℃, equipped with a variety of fixtures, suitable for different materials cold test, cooling speed is fast, 45 minutes up to -30 ℃.

$ 5468.00

Adopt cold Illuminant narrow-band interference Optical inspection system, Optical inspection stability is less than 0.002A/20min, support room temperature to 180 ℃ stepless temperature control, anti-chlorine interference up to 2000mg/L, batch processing of 20 water samples, easy to operate without changing pipes.

$ 1564.00

The three-box heat storage and cold storage structure is adopted, the temperature conversion time is ≤ 10 seconds, and the temperature recovery time is ≤ 5 minutes, which can realize the rapid Impact test of high temperature 150 ℃ to low temperature -55 ℃, and meet the environmental adaptability verification of the extreme temperature of the material.

$ 18437.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

Temperature range -30 ℃ to + 100 ℃, equipped with stainless steel inner and outer boxes and environmentally friendly refrigerant, supports multi-station fixture testing, can precisely control the folding mode and record data changes in real time.

$ 6113.00

Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.

$ 1647.00

It is suitable for low temperature bending resistance test of 32-63mm diaMeter silicon core tube. The sample needs to be kept at -20 ℃ +/- 2 ℃ for 2 hours, and there is no cracking or obvious stress blushing phenomenon after testing.

$ 2450.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.

$ 17307.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -20~ 100 ℃, fluctuation value +/- 0.1 ℃, built-in pressure suction pump maximum Flow rate 22L/min, support short time idling and low level protection function.

$ 2504.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.