Low-temperature light Incubator

The low-temperature light incubator controls the internal temperature through a refrigeration system and simulates day-night light cycles with an adjustable light source. It is used for experimental environments requiring controlled light and temperature conditions, such as plant growth studies and seed germination tests.
Selection
When selecting, pay attention to whether the temperature range and light intensity match the experimental requirements, and check the uniformity of the temperature field and light distribution. Confirm that the cooling method is suitable for the laboratory environment, and observe whether the operation interface is user-friendly. Consider the suitability of the internal volume and sample rack configuration.

Terms

Standards

Instruments

Using fluorine-free refrigeration system and mirror stainless steel liner, temperature range -40~ 65 ℃, with microcomputer intelligent control and independent temperature limit alarm function, support multi-stage programming and RS-485 communication interface.

$ 5245.00

Adopting mirror stainless steel liner and unique air duct circulation to ensure Temperature Uniformity +/- 1.5 ℃, 24-stage program can be set to simulate day and night changes, support 0~ 12000LX four-level adjustable light, safe temperature limit alarm.

$ 1369.00

With a wide range of -20~ 50 ℃ temperature control, temperature uniformity +/- 1 ℃, mirror stainless steel liner for easy cleaning, support low temperature compensation and RS485 interface connection, improve experimental accuracy and data recording convenience.

$ 4279.00

Mirror stainless steel liner for easy cleaning, temperature range -20~ 50 ℃, Temperature Fluctuation +/- 0.5 ℃, support low temperature compensation and RS485 interface connection, improve temperature control accuracy and data recording ability.

$ 1671.00

Temperature range -5~ 100 ℃, Temperature Fluctuation and Uniformity up to +/- 0.05 ℃, support a variety of temperature control media, with RS485 interface remote control and multiple safety protection functions.

$ 4592.00

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

With -20~ 50 ℃ wide temperature control, temperature uniformity +/- 1 ℃, equipped with stainless steel liner and low temperature compensation function, support RS485 interface connection recording equipment to meet the needs of precision experiments.

$ 3448.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Temperature range -10~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, Mirror stainless steel liner for easy cleaning, equipped with test holes and removable shelf support, support multi-stage programming and temperature limit alarm system.

$ 1934.00

Temperature range -40~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃; using environmentally friendly refrigerants and brand Compressors, the cooling time is reduced by more than 40% compared with traditional equipment, low energy consumption and low noise.

$ 4014.00

Using environmentally friendly refrigerant R134a, temperature control accuracy of +/- 0.5 ℃, equipped with independent temperature limit alarm system. Mirror stainless steel liner is easy to clean and supports multi-stage programming function for automatic control.

$ 4330.00

Microcomputer intelligent LCD controller, Temperature Fluctuation +/- 0.5 ℃, Low Temperature +/- 1 ℃, Double door structure and mirror stainless steel liner for easy cleaning, support multi-stage programming and RS-485 interface connection.

$ 3217.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -20~ 60 ℃, mirror stainless steel liner to prevent atomization, support thermostatic fostering and tissue cell preservation.

$ 2757.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

The mirror stainless steel liner is easy to clean, intelligent programmable control 24-stage program, Temperature Uniformity +/- 1 ℃, Illumrination degree 0~ 10000LX four-level adjustable, unique air duct to ensure uniform air supply does not hurt seedlings, temperature limit alarm to ensure safety.

$ 1116.00

Articles

Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.