Dry Sterilization Cabinet

The drying sterilizer generates high-temperature dry hot air through the heating of electric heating tubes, causing items inside the chamber to be continuously heated at a set temperature, thereby destroying the protein structure of microorganisms to achieve sterilization. It is used for the drying and sterilization of heat-resistant items such as laboratory glassware and metal tools.
Selection
When selecting, consider matching the chamber volume to the quantity of items to be processed. The temperature range must cover the sterilization requirements of 160-180℃, and attention should be paid to the heating speed and temperature uniformity. A stainless steel inner chamber facilitates cleaning, while dual-screen display and overheat protection features enhance operational safety.

Terms

Standards

Instruments

Using high temperature dry heat technology, temperature control accuracy of +/- 1 ℃, rapid heating and over-temperature protection function, studio volume 70L, easy and safe operation.

$ 574.00

Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.

$ 438.00

Adopt high temperature dry heat technology, Temperature range RT + 10~ 250 ℃, Input Power 1550W, with High Accuracy Microcomputer LCD display, automatic over-temperature protection and forced convection design, shorten disinfection time.

$ 716.00

The vertical unidirectional flow design prevents external gas from penetrating, with a cleanliness level of 100, an adjustable average wind speed of 0.3 to 0.6m/s, and a noise of less than 60dB. It is equipped with independent lighting and ultraviolet sterilization lamps.

$ 543.00

Temperature control accuracy +/- 1 ℃, rapid heating using forced convection mode, over-temperature automatic protection function to ensure safe operation, shelf can be moved to facilitate cleaning and maintenance in the box.

$ 961.00

Vertical unidirectional flow design prevents external gas penetration, adjustable wind speed of 0.3 to 0.6m/s, noise ≤ 60dB, equipped with ultraviolet sterilization and independent lighting, easy and safe operation.

$ 601.00

The use of low-energy centrifugal fans makes the airflow uniform and stable, with an average wind speed of 0.25 to 0.45m/s and noise less than or equal to 62dB (A). The mirror stainless steel countertop is corrosion-resistant and easy to clean, and the tripod and cabinet are separated for easy transportation.

$ 1013.00

Equipped with ultraviolet sterilization system to effectively prevent pollution, temperature control accuracy of +/- 0.3 ℃, support multi-stage programming and independent temperature limit alarm, to ensure the safety and stability of the experiment.

$ 943.00

Microcomputer intelligent control ensures precise temperature control, Temperature Fluctuation +/- 0.5 ℃ and uniformity up to 1 ℃. Equipped with UV sterilization function and stainless steel liner, support low temperature compensation, volume 300L to meet the diverse needs of foster.

$ 1226.00

With UV sterilization function to reduce the risk of contamination, Power 12-1200W is continuously adjustable, supports 0.2-500 ml crush capacity, can store 20 sets of programs and realize remote monitoring.

$ 3535.00

With UV sterilization function to reduce the risk of cross contamination, Power 10-1000W is continuously adjustable, supports 0.1-700 ml crush capacity, can store 20 sets of programs and realize electric lifting operation.

$ 3010.00

Using professional refrigeration technology implementation 5-50 ℃ wide range of temperature control, temperature uniformity up to 1 ℃; equipped with ultraviolet sterilization lamp can be directly observed foster, stainless steel liner to ensure long-term use without corrosion.

$ 1146.00

Temperature uniformity is improved by fan speed control, the independent air duct circulation system automatically discharges water vapor, the dry culture mode is automatically converted, the temperature control accuracy fosters +/- 0.5 ℃, drying +/- 1 ℃, and the double door structure insulation does not affect the temperature in the box.

$ 722.00

With UV sterilization function to reduce the risk of cross-contamination, Power 18-1800W continuously adjustable, crushing capacity 1-1200ml, support remote control and electric lifting, flexible and convenient operation.

$ 4059.00

Microcomputer PID control technology is used to keep the temperature accurate and constant, equipped with ultraviolet sterilization lamp to effectively kill microorganisms, CO2 recovery time ≤ concentration value × 1.2 minutes, unique air circulation to ensure temperature uniformity.

$ 1834.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking