Cold and Hot Circulating Water Bath

The cold and hot circulating water bath alternates between the heater and chiller to circulate the liquid in the tank within the set temperature range. It is used for material temperature resistance testing, such as coating curing and plastic aging experiments.
Selection
When selecting, consider that the temperature range covers experimental needs, temperature control accuracy meets standards, tank capacity accommodates sample size, circulation pump flow ensures uniform temperature, and corrosion-resistant materials are suitable for experimental liquids.

Terms

Standards

Instruments

Adopt independent control structure of hot and cold box, temperature conversion time ≤ 15 seconds, temperature recovery ≤ 5 minutes, equipped with safety interlock protection and 7-inch Touchscreen controller, support long-term adjustable test.

$ 42981.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.

$ 38608.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

Adopt -80 ° C cold trap temperature and 4kg/batch water, equipped with pre-freezing function without additional equipment, color Touchscreen display paraMeters, support for a variety of container freeze-drying and automatic maintenance reminders.

$ 6281.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

The use of professional gas diversion technology has good water capture effect, and the cold trap temperature reaches -80 ° C to capture 4kg of water. Support sample pre-freezing and lyophilization of various containers, with data export and remote control functions, built-in maintenance reminders and vacuum alarm systems.

$ 5358.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.

$ 1647.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Danfoss Compressor to achieve -60 ℃ low temperature, water capture up to 4kg/batch. With cold trap pre-freezing function without additional equipment, color Touchscreen display operating paraMeters, support data export and remote control.

$ 3974.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.