Concentration Meter

Concentration meters determine the solute content ratio by measuring the absorption of light at specific wavelengths or changes in the refractive index of a solution. They are used to monitor chemical ratios in production processes, the dosage of agents in wastewater treatment, and the quality inspection of finished products.
Selection
Select the model based on optical or ultrasonic principles according to the properties of the substance to be measured; consider whether the measurement range covers the actual concentration interval; confirm the corrosion resistance of the sensor material; check the automatic temperature compensation function; evaluate the on-site installation method and protection rating.

Terms

Standards

Instruments

Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.

$ 11079.00

The diazotization method is used to react with nitrite to generate pink color. Measurement range is 0~ 600μg/L, and 100 tests are provided. It is suitable for a variety of Photometers to ensure accurate and reliable concentration determination.

$ 186.00

Volume 12 liters, the concentration of 5% -35%, equipped with manual speed regulation and digital Rotation speed display function, stainless steel material and new sealing technology to prevent leakage.

$ 3946.00

Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.

$ 215.00

Measurement range 0.0~ 12.5 ppm, accuracy +/- 0.1 ppm +/- 5% of reading, fast and easy Ion concentration detection based on DPD method.

$ 215.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ElectRode, Measurement accuracy +/- 0.5% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Imported stainless steel liner and independent ozone concentration controller, temperature control accuracy of +/- 0.5 ℃, equipped with static tensile fixture and rotational speed adjustable sample rack, support long-term stable operation.

$ 10643.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and a variety of concentration units, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement range 5 × 10~ 1M.

$ 864.00

Measurement range 6.35μg/L to 63.5mg/L, resolution up to 0.01 pCu, support pCu and concentration conversion, easy operation and high Stability.

$ 382.00

Three concentration units of honey can be measured, Brix range 58~ 92%, Be 'range 38~ 43 °, Water range 12~ 27%, scale reading method, small size only 155mm, light weight 160g.

$ 122.00

Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.

$ 519.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Colorimetric measurement using Nessler method. Measurement range is 0.0~ 100.0 ppm ammonium. 100 tests are provided. Yellow shade is generated for concentration determination.

$ 257.00

Using 6.44ppt high concentration calibrated liquid, Encasement alone to ensure freshness, light block Encasement anti-ultraviolet oxidation, valid period of up to 5 years, suitable for field and portable use.

$ 167.00

Articles

How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.