The fixed infrared thermometer converts infrared radiation energy emitted from the surface of an object into electrical signals and calculates the temperature value. It is used for non-contact continuous monitoring of surface temperatures, suitable for applications such as production lines and equipment monitoring that require fixed-point temperature measurement.
Selection
When selecting, consider that the temperature measurement range covers actual needs, measurement accuracy meets application standards, response time matches the rate of change of the monitored object, installation methods adapt to the on-site environment, protection levels satisfy working conditions, and signal output interfaces are compatible with existing systems.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Instruments

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Using 45/0 ring lighting and concave grating spectroscopy technology, the measurement diaMeter is Φ 20mm, the non-contact measurement distance is 7.5mm, and the chromatic value Repeatability is within 0.03. Color difference formula and chroma index analysis are supported.

$ 8109.00

Adopt 45/0 structure, measurement Repeatability dE * ab ≤ 0.02, Inter-instrument Agreement dE * ab ≤ 0.25, support non-contact detection, waterproof and dustproof IP66, multiple communication interfaces, LED Illuminant long life.

$ 3946.00

Adopt 45/0 ° ring illumination and concave grating spectroscopy, measurement wavelength 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination, support a variety of Measurement modes and camera positioning.

$ 8109.00

Using 45/0 ring lighting and concave grating spectroscopy technology, measurement Wavelength range 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination and damage, support a variety of Measurement modes and camera positioning.

$ 7464.00

Optical inspection structure of 45/0 °, non-contact distance of 7.5mm, measurement wavelength of 400-700nm, avoid sample contamination and damage, support a variety of Measurement modes and High Accuracy Color Analysis.

$ 7464.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Measurement range 200-20000 rpm, accuracy of +/- (1 × 10 × reading + 1) rpm, support non-contact speed measurement and steering determination function.

$ 198.00

The non-contact grating optocoupler Sensor is used to automatically collect data, with a nominal kinetic energy of 2.207J, supports automatic calculation of intensity and voice broadcast, and has a built-in steel anvil calibration function to improve detection efficiency and accuracy.

$ 369.00

Non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 < 0.2, high measurement Stability, supports more than 30 Color indicators and 28 kinds of observation Illuminants, compact and easy to carry.

$ 332.00

The equipment temperature range -50~ 750 ℃, object distance ratio 12:1, Response Time 500ms, with non-contact measurement, High Accuracy and Fast Response characteristics, suitable for a variety of industrial scenarios.

$ 95.00

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Using 45/0 ring illumination and concave grating spectroscopy technology, the measurement diaMeter is 20mm, and the non-contact distance is 7.5mm. With 256 pixel dual array CMOS sensor, Wavelength range 400~ 700nm, chromatic value Repeatability Delta E * ab 0.05, supports a variety of Color space and color difference analysis.

$ 7464.00

Articles

Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Rotational Viscometer vs. Stormer Viscometer: How to Choose the Right Instrument Based on Coating Type
The rotational viscometer measures viscosity by detecting rotor torque and can analyze rheological properties at different shear rates, making it suitable for research and precise measurements. The Stormer viscometer uses the load at a fixed rotational speed to determine the KU value, simulating construction conditions, and is commonly used for rapid on-site evaluation of coating application performance.