Portable Dissolved Oxygen Meter (for gas)

Portable oxygen detectors measure the oxygen concentration in gases using electrochemical sensors, where oxidation-reduction reactions occur to generate current signals. They are used for on-site monitoring of oxygen levels in industrial production environments, confined spaces, and other areas to ensure operational safety.
Selection
When selecting, consider whether the detection range covers 0-30% oxygen concentration, with a resolution of 0.1%. Ensure the protection rating is IP54 or higher and that it includes audible and visual alarm functions. Check the sensor lifespan and calibration cycle, and opt for models with temperature compensation to adapt to different environments. Verify that the data logging function and battery life meet on-site requirements.

Terms

Standards

Instruments

The use of PTFE oxygen permeable membrane to ensure oxygen permeability, spiral cap design for easy installation and electrolysis filling, suitable for Portable dissolved oxygen measurement equipment maintenance.

$ 243.00

Measurement range of 50ppm dissolved oxygen and 600% Saturation, support pressure, temperature and salinity automatic compensation, can be used continuously for about 200 hours, with IP67 waterproof rating.

$ 1409.00

Using high density polyethylene (PE) oxygen permeable membrane to achieve efficient oxygen diffusion, equipped with ABS plastic screw cap structure for easy installation and electrolysis filling, and interact with the current system for accurate measurement of dissolved oxygen concentration.

$ 243.00

Polarography dissolved oxygen Measurement range 0.00~ 50.00mg/L, Response Time ≤ 45s, support automatic temperature compensation and salinity compensation, with IP65 Protection Rating, Data storage 500 sets and GLP standards.

$ 674.00

With conductivity 0-2000mS/cm and dissolved oxygen 0-20mg/L wide range measurement, support automatic temperature compensation and air pressure compensation, 3.5 inch color screen display, data storage capacity of 3000 groups, Protection Rating is IP57.

$ 670.00

Optical inspection fluorescence technology for measurement of dissolved oxygen, no polarization time, fast Response and not affected by Flow velocity; Built-in temperature sensor, Measurement range 0.00-50 mg/L, accuracy up to 1.5% +/- 0.01mg/L; Protection Rating IP68, suitable for harsh environments.

$ 3401.00

Polarographic coating ElectRode, Response Time no more than 30 seconds, automatic temperature compensation range 0~ 40 ℃, portable design for easy field operation, Measurement range 0.0~ 20.0mg/L, accuracy +/- 0.3mg/L.

$ 175.00

Equipped with polarographic dissolved Oxygen electRode, Measurement accuracy +/- 0.5mg/L, support automatic temperature compensation and manual salinity compensation, full waterproof design to ensure harsh environment use, built-in a number of custom paraMeter settings.

$ 361.00

With pH, ORP, dissolved oxygen three measurement functions, support automatic temperature compensation and salinity compensation, built-in 500 data storage, equipped with USB Communication interface, Measurement accuracy of +/- 0.002pH.

$ 630.00

Sterling silver cathode and zinc anode construction, integrated temperature sensor for instant measurement without conditioning time, thin permeable membrane isolates Sensor and allows oxygen to pass, generating current to determine oxygen concentration.

$ 162.00

Supports pH, conductivity, dissolved oxygen and other 9 paraMeter measurement, equipped with 3.5 inch color screen and 3000 data storage, with IP57 Protection Rating and Type-C charging interface, suitable for on-site rapid detection.

$ 950.00

Polarographic probe accurate to 0.3ppm, equipped with 4 Meters of cable to facilitate measurement of hard-to-reach areas; automatic temperature compensation range 0.0-50 ℃, support salinity and height compensation to ensure on-site data Reliability.

$ 1027.00

Support pH, dissolved oxygen, ORP and temperature Multi-ParaMeter measurement, with 3000 sets of data storage capacity and IP57 Protection Rating, using 3.5 inch color screen and intelligent Operating system, providing automatic temperature and pressure compensation function.

$ 745.00

With pH, ORP and dissolved oxygen three measurement functions, support 1-5 point calibrating and automatic ElectRode diagnosis, can store 500 sets of data and have USB Communication interface, Measurement accuracy of +/- 0.002pH and +/- 0.2mg/L.

$ 593.00

PTFE oxygen permeable membrane ensures oxygen permeability, ABS plastic material enhances durability, screw cap design simplifies installation process, suitable for long-term water quality monitoring applications.

$ 243.00

Articles

Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Ozone Aging Test Chamber Evaluates Crack Resistance of Rubber
This article introduces how an ozone aging test chamber is used to evaluate the crack resistance of rubber. Ozone is a common factor that causes rubber aging. The test chamber simulates an ozone-containing environment, applies strain to rubber samples, and accelerates their aging process.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Differential pressure method gas permeameter measures oxygen transmission rate of films.
This article introduces the method of measuring the oxygen transmission rate of films using the differential pressure gas permeation apparatus.
Differential scanning calorimetry for determining the glass transition temperature of epoxy resin
Differential scanning calorimetry analyzes the thermal properties of materials by measuring the heat flow difference between the sample and a reference material.
Differential Scanning Calorimetry Study on the Curing Reaction Kinetics of Epoxy Resin
This article introduces the method of using differential scanning calorimetry to study the curing reaction kinetics of epoxy resins.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.