Digital Powder Agitator

The digital powder mixer uses a motor to drive the mixing blades, ensuring uniform blending of powders within the container. The digital display screen shows real-time speed and time parameters. It is used in laboratories for mixing and preparing powder materials such as coatings and plastics, ensuring sample consistency.
Selection
Select the stirring capacity and material based on the powder characteristics; use stainless steel containers for corrosive materials. Verify that the speed range matches the sample requirements, and observe whether the stirring structure creates dead zones. Confirm that the digital display function allows precise control of time parameters, and check the equipment's operational stability and safety protection design.

Terms

Standards

Instruments

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Double pulse Back flushing automatic powder cleaning, Laminating filter accuracy of 0.3 microns, powder gas separation efficiency, stainless steel material is durable, color change operation is simple, improve dust recovery efficiency.

$ 1655.00

Using fixed funnel method to measure powder flowability, equipped with 10mm inner through Glass funnel and 0-100mm scale struts, can accurately measure cone height, meet the requirements of Pharmacopoeia and ISO standards.

$ 535.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

The stainless steel funnel is used to ensure that the surface is smooth and free of static electricity. It is equipped with two specifications of funnel, which are suitable for free-flowing powder and caking trend powder respectively. The receiver volume is 500ml, and the sampling volume is 510-550ml, which meets the standard test requirements.

$ 875.00

Four 25 ° inclined quartz Glass baffles are used to guide the powder flow and are equipped with a 25 +/- 0.05ml standard cylindrical Cup to achieve a loose powder state through natural gravity, ensuring the accuracy and Repeatability of density testing.

$ 687.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

Vibration amplitude 50mm, can test 3 samples at the same time, Test accuracy error is less than +/- 1.5%, stainless steel structure, suitable for battery materials and other powder Tapped Density measurement.

$ 1361.00

The volume weighing method is used to measure the density of free-flowing powder, the diaMeter of the funnel is 60mm, and the volume of the receiver is 500ml. It is suitable for powders with caking trend, and the test process avoids static electricity.

$ 711.00

It can simultaneously measure more than 10 physical paraMeters such as angle of repose and tap density. The vibration frequency is 300 rpm, and the repeatability error is ≤ 3%. It supports a variety of national standard test methods to meet the needs of comprehensive characteristic analysis of powder.

$ 5528.00

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

With 0.001g/cm ³ density accuracy and 0.001g weighing accuracy, it supports solid, liquid, powder and Water Absorbency sample testing, and has built-in multiple density reference and direct density display functions.

$ 525.00

The standard funnel method is used to test the flow time of 50g metal powder. Equipped with 2.5mm and 5.0mm pore diaMeter stainless steel funnel, the Loose Bulk Density measurement can be completed with 25ml glassgraduates with scale, and the structure is stable and anti-deformation.

$ 525.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.