Curved Surface Roughness Inspector

The surface roughness tester records microscopic undulations by sliding a stylus over the curved surface, converting them into electrical signals for analyzing profile parameters. It is used to measure the surface texture of curved workpieces and is applied in quality control for curved components such as bearings and molds.
Selection
When selecting, consider the curvature range of the surface and its compatibility with the instrument's probe. The measurement accuracy must meet product standards, while environmental vibrations may affect stability. The software should be capable of processing three-dimensional surface data, and the probe material must be suitable for the hardness of the measured surface.

Terms

Standards

Instruments

The support ring contains 12 different models, covering the R10 to infinity surface range, suitable for inner and outer cylindrical and spherical surface measurement, ensuring the accuracy and Stability of surface hardness testing.

$ 251.00

DSP chip control, Measurement speed and low power consumption; Support 160μm large-range measurement, up to 320μm; Multi-ParaMeter measurement function, compatible with ISO, DIN, ANSI, JIS multiple national standards.

$ 1364.00

It can be extended by 50mm, and up to 2 pieces can be installed to achieve 100mm deep hole measurement; it is suitable for deep hole internal surface roughness detection, and needs to cooperate with the measurement platform to ensure Stability.

$ 157.00

Measurement range from 5mm, depth up to 22mm, suitable for a variety of Roughness Gauge to achieve profiled surface detection.

$ 275.00

It can measure planar and cylindrical surface roughness, with a minimum diaMeter of 5mm and a maximum depth of 22mm, and supports a variety of Sensors to adapt to different workpiece shapes.

$ 332.00

It can measure the surface roughness of the hole with an aperture greater than 2mm, and the maximum depth is 9mm. It supports both flat and cylindrical measurement, and is suitable for a variety of special-shaped surface detection needs.

$ 425.00

High-speed DSP processor is used to improve Measurement speed, support Ra0.05-10.0 μ m Measurement range, Sensor host integrated design is convenient for field use, and can measure the cone surface and groove of the outer circle.

$ 1145.00

Using DSP chip control, Measurement range Z axis 160 microns, X axis 17.5 mm, Continuous Operating Time more than 20 hours, support RC, PC-RC, GAUSS, D-P filter.

$ 683.00

It can measure the groove surface roughness with a groove width greater than 3mm and a groove depth less than 10mm, and is compatible with flat and cylindrical measurement. It can be used with the measurement platform to achieve accurate detection.

$ 425.00

Provide 25, 40, 70, 100 four profile specifications, size 87x87x2.5mm, weight only 60 grams, Portable design is convenient for quick comparison and evaluation on site.

$ 505.00

Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.

$ 935.00

Small size only 106 * 70 * 24mm, weight 200 grams easy to carry; measurement of outer circle, cone, plane and groove, Indication Error ≤ +/- 15%, using piezoelectric crystal Sensor to ensure measurement Reliability.

$ 687.00

Measurement beam of light diaMeter 1.5mm, measurement window 4mmx2mm, suitable for facet and small curvature surface measurement, low energy consumption single battery can last for more than 58 hours.

$ 428.00

Using 2.0MHz Frequency, specially designed for cast iron and other coarse crystal materials, concave curved surface structure is suitable for special workpiece shape, Measurement range covers 2.0~ 400.0mm, and the lower limit of pipe measurement is Φ 30 * 4mm.

$ 283.00

Measurement range 0~ 500μm, stylus angle 60 degrees, can measure more than 50 readings per minute, with built-in temperature compensation and aluminum oxide wear surface design, in line with ASTM D4417 and other international standards.

$ 1437.00

Articles

Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Contact angle measuring instrument measures the surface wettability of paper.
The contact angle goniometer evaluates wettability by measuring the contact angle of a liquid droplet on the surface of paper, based on the principle of Young's equation. The static drop method is commonly used for measurement, requiring control over sample flatness, environmental conditions, and droplet volume, while also considering the influence of surface roughness.
Surface Roughness Tester Evaluates the Impact of Substrate on Adhesion
This article primarily explores how the surface roughness of the substrate affects the adhesion of coatings or bonds.
Paper smoothness and roughness
Paper smoothness and roughness are key parameters that describe the flatness of the paper surface, and they complement each other. Smoothness refers to the extent to which the paper surface approaches an ideal plane, while roughness reflects the amplitude and frequency of surface irregularities.