Temperature Monitoring Recorder

The temperature monitoring recorder collects temperature data through sensors, stores information on an internal memory chip, and can be connected to a computer to export curves. It is used for real-time monitoring of environmental or equipment temperature changes, commonly seen in scenarios such as warehousing and transportation, laboratory temperature control, and production process monitoring.
Selection
When selecting, focus on matching the measurement range and accuracy to your needs, check the protection rating for environmental suitability, confirm battery life and storage capacity, verify the compatibility of data export methods, check the validity of the calibration certificate, and compare the installation convenience of different mounting options.

Terms

Standards

Instruments

Using Bluetooth low energy wireless transmission, easy to set up and download, Measurement range (temperature -40~ 100 ℃, Humidity 0-100% RH), high accuracy (temperature +/- 0.2 ℃), and has a weatherproof shell and visual alarm function, suitable for long-term outdoor monitoring.

$ 351.00

Non-contact Sensor with long life and two Measurement ranges (100 to 55000 μS/cm). The enclosure is made of Acetal Resin, which is resistant to seawater corrosion and supports monthly on-site calibrating for accuracy, with a maximum operating depth of 70 Meters.

$ 1719.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Waterproof depth of 120 Meters, suitable for long-term underwater deployment. Bluetooth low energy wireless connection, easy to set up and data download. Built-in large memory can store 98000 measurements, users can replace the battery by themselves. With water detection function to save power, Temperature Measurement accuracy is +/- 0.2 ℃.

$ 315.00

With built-in and external dual temperature sensors, the temperature range covers -40.0 to 125.0 ° C, IP67 waterproof and dustproof, supports data storage of up to 16,000 readings, and can prompt temperature abnormalities through LED alarms.

$ 272.00

Bluetooth low energy wireless connection, easy to set up and download; waterproof depth of 1500 Meters, durable for long-term underwater deployment; built-in large memory can store 98000 measurement data; with water detection function to save Battery life.

$ 330.00

Using Bluetooth wireless communication, support setting and data reading through mobile phone or tablet within 30.5 Meters. The accuracy is up to +/- 0.2 ° C and +/- 2% RH, can store more than 84000 Measured values, and has sound and light alarm function.

$ 328.00

Support Bluetooth wireless setting and download, waterproof depth of 30 Meters, memory can store 96000 Measured values, users can replace the battery by themselves, and have temperature threshold LED alarm function.

$ 235.00

Optical inspection dissolved oxygen Sensor technology, strong and durable, measurement depth of 100 Meters, accuracy of +/- 0.2mg/L (8mg/L). Probe removable replacement, easy maintenance, suitable for long-term underwater monitoring.

$ 2387.00

Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.

$ 414.00

Using Bluetooth low energy technology, support wireless settings and data download, waterproof depth of 30 Meters, accuracy of +/- 0.5 ℃, Storage capacity of 98,000 measurements, users can easily replace the battery.

$ 202.00

Using External Sensor, Humidity accuracy of +/- 0.2 ℃ and +/- 2.5% RH respectively, Humidity Response Time as fast as 15 seconds. With Bluetooth wireless setting and download, weatherproof shell, support mobile end real-time viewing and data sharing.

$ 477.00

Precision up to +/- 1 ° C error, can observe the melting state at a distance, visually display temperature changes, suitable for temperature monitoring of various electrical equipment connection parts.

$ 86.00

Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.

$ 294.00

Support up to 4 kinds of gas simultaneous detection, integrated temperature and Humidity monitoring function, with Internet of Things remote monitoring capability, dual temperature Humidity design to achieve physical and software double compensation, Protection Rating up to IP66.

$ 404.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.