Film High and Low Temperature Alternating Damp Heat Test Chamber

The film high-low temperature alternating damp heat test chamber simulates different temperature and humidity environments in a sealed space through a refrigeration and heating system and a humidity control device. It is used to detect the performance changes of materials such as film under varying temperature and humidity conditions, commonly employed in quality verification during film production and storage processes.
Selection
When selecting, consider that the temperature and humidity range should cover the actual usage environment, the chamber volume should match the sample size, the temperature change rate should meet the test standard requirements, the control system should be easy to operate and reliable, and the recording function should meet the needs for data traceability.

Standards

Instruments

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range -70~ 150 ℃, Temperature Uniformity +/- 2 ℃, using multi-layer conductive film observation window and upper air supply and lower air return system, support 120 sets of program settings and continuous PID control, with multiple safety protection mechanisms.

$ 8093.00

Using stainless steel mirror liner and French Taikang Compressor, temperature range -60~ 150 ℃, Fluctuation ≤ +/- 0.5 ℃, equipped with large screen Touchscreen and multiple safety protection system, high test accuracy and stable and reliable.

$ 7222.00

Temperature range -30~ 150 ℃, studio volume 800L, multi-layer conductive film observation window and independent over-temperature protector, with 120 sets of program settings and continuous PID control function.

$ 10336.00

Temperature range -30~ 150 ℃, studio volume 500L, using multi-layer conductive film observation window and PID continuous control, with 120 sets of program settings and multiple safety protection systems to ensure stable and reliable testing.

$ 8900.00

Temperature range -40~ 150 ℃, Temperature Uniformity ≤ +/- 2 ℃, equipped with multi-layer conductive film observation window and independent over-temperature protector, support 120 sets of program settings and power-off recovery functions to ensure stable and reliable test process.

$ 7125.00

Adopt porcelain frame nickel-chrome wire heater and shunt cooling method, temperature control accuracy +/- 0.5 ℃, support 120 sets of program setting and power failure recovery function, equipped with multi-layer conductive film observation window and independent over-temperature protection device.

$ 9707.00

Temperature range -70~ 150 ℃, Temperature Uniformity ≤ +/- 2 ℃, equipped with multi-layer conductive film observation window and independent over-temperature protector, support 120 sets of program settings and power-off recovery functions to ensure stable and reliable test process.

$ 10659.00

Temperature range -70~ 150 ℃, studio volume 800L, using multi-layer conductive film observation window and ultra-fine Glass insulation cotton, with 120 sets of program settings and continuous PID control function.

$ 12111.00

Adopt the upper air supply and lower air return mode to ensure Temperature Uniformity ≤ +/- 2 ℃, with 120 sets of program settings and 0~ 999h timing function, built-in multi-layer conductive film observation window and independent over-temperature protection device.

$ 6496.00

Temperature range -30~ 150 ℃, Temperature Uniformity ≤ +/- 2 ℃, equipped with multi-layer conductive film observation window and independent over-temperature protector, support 120 sets of program settings and power-off recovery functions to ensure stable and reliable test process.

$ 11288.00

With a wide temperature range of -40~ 150 ° C and +/- 0.5 ° C Fluctuation, the upper air supply and lower return air circulation mode are adopted, and the multi-layer conductive film observation window and independent over-temperature protector are equipped to ensure the stability and reliability of the test process.

$ 6657.00

Temperature range -20~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, stainless steel studio and high efficiency refrigeration system, support high and low temperature alternating test.

$ 4366.00