High-Low Temperature Constant Temperature Test Box

The high and low temperature constant temperature test chamber controls the internal temperature through refrigeration and heating systems to simulate the performance changes of materials under extreme temperatures. It is used to test the stability and durability of products such as coatings and plastics in set temperature environments, and is commonly applied in product quality verification and research and development testing.
Selection
When selecting, consider that the temperature range should cover testing needs, the chamber size should fit the sample dimensions, and temperature fluctuation and uniformity should meet standards. Pay attention to the cooling method, safety protection, and energy consumption to ensure equipment reliability and long-term operational stability.

Terms

Standards

Instruments

Adopt three-box structure to achieve rapid temperature conversion, conversion time ≤ 10 seconds, temperature control accuracy of +/- 0.5 ℃, equipped with air passage switching system and microcomputer equilibrate temperature control system to ensure test Stability.

$ 24150.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

The three-box structure realizes independent temperature control in the high temperature and low temperature area, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, the air circuit switching Impact mode is adopted, and the microcomputer equilibrating temperature control system is equipped.

$ 20712.00

The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.

$ 21858.00

Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.

$ 6157.00

Adopt French Taikang Compressor refrigeration system, Temperature Uniformity ≤ +/- 2 ℃, equipped with independent temperature limit alarm and double-decked Glass observation window, support 0~ 9999 minutes timing and 50mm test hole.

$ 8820.00

The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.

$ 17307.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

The French Taikang Compressor unit is used to ensure stable cooling, the 7-inch large screen realizes simple programming and monitoring, Temperature Uniformity +/- 2 ℃ and humidity deviation is small, and the independent temperature limit alarm system improves the experimental safety.

$ 7625.00

The three-box structure realizes independent temperature control in the high temperature zone, the low temperature zone and the test zone. The temperature conversion time is within 10 seconds, and the temperature control accuracy reaches +/- 0.5 ° C. The air circuit switching method is used for rapid Impact testing to improve the material testing efficiency.

$ 30217.00

Using French Taikang Compressor and multi-wing circulation system, Temperature Uniformity +/- 2 ℃, support 0-9999 minutes timing, with independent temperature limit protection and automatic humidification control function.

$ 9885.00

Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.

$ 20261.00

The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.

$ 34606.00

Temperature range -20~ 150 ℃, studio volume 408L, suitable for high temperature and low temperature Reliability test, support constant temperature test, in line with a number of national standards.

$ 6076.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.