The laboratory circulation pump uses an electric motor to drive the impeller, creating a negative pressure that enables continuous liquid flow within a closed pipeline. It is used for temperature control in devices such as constant temperature baths and reaction vessels, ensuring uniform circulation of the medium.
Selection
Match pump parameters based on required flow rate and head, select corrosion-resistant materials considering the corrosiveness of the medium, choose sealing methods according to the operating temperature, determine pump body structural dimensions based on installation space, and verify interface specifications to ensure pipeline compatibility.

Terms

Standards

Instruments

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature control accuracy of +/- 0.1 ℃, temperature fluctuation of +/- 1 ℃, equipped with domestic circulation to ensure uniform temperature, external circulation pump can lead liquid heating, LED double window digital display easy to operate, thermal insulation material efficient, Benchtop compact structure.

$ 911.00

Temperature range -30~ 25 ℃, Temperature Stability +/- 2 ℃, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, high temperature lifting speed, can provide large Flow rate circulation and multi-functional low temperature operation support.

$ 2541.00

Two-stage pump structure is equipped with PTFE material pump head, strong corrosion resistance, maximum Flow rate 125L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise and low temperature rise.

$ 3630.00

PTFE material pump head structure can resist strong chemical corrosion, double-stage pump design to achieve 6-8mbar Ultimate vacuum degree, oil-free dry operation to ensure complete recovery of solvent, noise less than 55dB quiet and stable operation.

$ 1397.00

Temperature control accuracy of +/- 2 ℃, the maximum Flow rate 20L/min; using SUS304 and polymer anti-corrosion material circulation system, with large capacity open Bath and external circulation integrated design, lifting temperature fast and anti-corrosion.

$ 1014.00

Temperature control accuracy +/- 0.1 ℃, domestic circulation direct test, external circulation provides thermostatic medium through high voltage pump, with LED display and multiple Safety protection, motor and circulation pump low heat efficiency.

$ 951.00

Temperature control accuracy +/- 2 ℃, cooling capacity up to 1860W, equipped with large capacity open Bath and external circulation system, using anti-corrosion material circulation pipeline, lifting temperature fast and reliable operation.

$ 1810.00

The integrated pump structure is adopted, and the forced oil pump lubrication system ensures stable operation. The ultimate pressure can reach 0.005mbar, and the noise value is only 58dB. The special gas ballast valve is designed to effectively extract steam without polluting the oil quality.

$ 645.00

PTFE material pump head and composite diaphragm, Maximum Flow rate 20L/min, Ultimate vacuum degree 15-20mbar, with anti-corrosion, low noise, overheating protection function, suitable for corrosion environment.

$ 916.00

Using PTFE pump head and composite diaphragm, strong corrosion resistance, maximum Flow rate 35L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise operation stability.

$ 1085.00

Adopt proportional refrigeration and PID technology, temperature fluctuation +/- 0.5 ℃, support high temperature direct drop and short-term idling of pump head, Flow rate 22L/min, head 10m, long impurity resistance life.

$ 2258.00

PTFE material corrosion-resistant structure, pumping rate of 20L/min, two-stage pump design to ensure high Vacuum Level, oil-free dry operation maintenance-free, noise less than 55dB quiet operation.

$ 1203.00

Adopt high-performance non-heat circulating pump to avoid traditional pump self-generated heat; Temperature control accuracy of +/- 0.1 ℃, Temperature range -40~ 100 ℃; with power-off protection, over-temperature alarm, low level air burning protection and other multiple safety functions to ensure stability and reliability.

$ 2150.00

The integrated pump body structure is adopted, and the forced oil pump lubrication is controlled. The ultimate pressure can reach 0.005mbar, the noise is as low as 58dB, and the parts are few and easy to maintain.

$ 698.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.