AFNOR Viscosity Cup for Coatings

The AFNOR viscosity cup determines viscosity by measuring the time it takes for a fluid to flow out through a standard aperture at the bottom of the cup. It is used for viscosity control and quality testing of fluids such as coatings and inks, in compliance with the French AFNOR standard.
Selection
When selecting, consider the viscosity range of the fluid being measured to match the cup aperture type. Choose the corresponding specifications according to industry standards, and pay attention to the corrosion resistance and temperature adaptability of the cup material. Ensure that the measurement environment meets standard conditions.

Terms

Standards

Instruments

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 6mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability.

$ 438.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 8mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability, suitable for liquid viscosity testing.

$ 438.00

Made of titanium anodic oxidation aluminum, the diaMeter of the flow hole is 2.5mm, and each Cup is engraved with an independent serial number, which is suitable for accurate measurement of liquid viscosity in the laboratory.

$ 438.00

Using titanium anodic oxidation aluminum material, flow hole diaMeter 4mm, Cup height 75mm, corrosion resistance and lightweight, each Cup engraved with an independent serial number to ensure accurate and reliable measurement.

$ 438.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.

$ 167.00

Using stainless steel aperture 5.20mm, viscosity measurement range of 200~ 1200cSt, aluminum alloy Cup body sturdy and durable, in line with ASTM D1200 standard, suitable for laboratory accurate measurement of fluid viscosity.

$ 170.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 5.2mm, the viscosity measurement range is 200~ 1200cSt, the outflow time is 20~ 105 seconds, and the liquid viscosity is evaluated by the flow time.

$ 130.00

Portable design with long stainless steel handle for easy operation. Outflow aperture 5.8mm, can measure 200-1200cSt viscosity range, corresponding to outflow time 30-100 seconds. Cup body aluminum alloy with stainless steel nozzle, both lightweight and corrosion resistance.

$ 285.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 3.40mm, the viscosity measurement range is 49~ 220cSt, and the outflow time is 25~ 105 seconds.

$ 130.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.