Low Temperature Flex Resistance Testing Machine

The low-temperature flex testing machine maintains the specimen at a set low temperature through a refrigeration system, while a mechanical device repeatedly bends the specimen to evaluate the material's flexibility and resistance to cracking in low-temperature environments. This equipment is used to verify the low-temperature adaptability of materials such as coatings, plastics, and rubber, ensuring that products perform reliably under cold conditions.
Selection
When selecting a low-temperature flex resistance testing machine, it is essential to consider the temperature range covering the actual usage environment, the bending angle and frequency complying with testing standards, the fixture compatibility with sample dimensions, the temperature control accuracy meeting repeatability requirements, the robust and durable equipment structure, and a user-friendly operation interface.

Terms

Standards

Instruments

Temperature range -25 ℃, temperature control accuracy +/- 1 ℃, can simulate the natural low temperature environment for bending test, observe material changes, determine the degree of cold resistance.

$ 6770.00

High borosilicate Glass material, corrosion resistance and high and low temperature resistance, strong ability to withstand thermal Impact; vacuum negative pressure can reach 0.095MPa, support material reaction under negative pressure; Overhead Stirrer Rotation speed 50-500rpm, torque 70N.cm, suitable for a variety of viscosity materials.

$ 2465.00

4-Terminal Resistance Measuring method is used to eliminate the influence of wire resistance. Test speed is up to 6 times/sec. Measurement current is less than 100mA to prevent temperature drift and ensure Precision and Stability.

$ 146.00

Temperature control accuracy of +/- 0.3 ℃, support for the installation of a variety of folding fixture, suitable for different materials in low temperature environment folding performance test.

$ 6205.00

Using high borosilicate Glass material, corrosion resistance and can withstand -80~ 200 ℃ Operating temperature, vacuum negative pressure of 0.095MPa, equipped with PTFE four-leaf stirringRod and RWD50 top Stirrer, Speed range 50~ 500rpm, support precise control and uniform material reaction.

$ 2675.00

The use of national standard 06Cr19Ni10 stainless steel precision machining, high temperature resistance up to 300 ℃, low temperature resistance to -100 ℃, hardness ≤ 187HB, with acid and alkali resistance, grinding anti-sinking, anti-stick, suitable for dry grinding and wet grinding.

$ 154.00

Using 2-wire method and 3-wire method measurement, Ground Voltage Measurement range 0~ 200V, Ground Resistance Measurement range 0~ 1999 Ω, Response Time about 5 seconds, with continuous measurement and overload protection function.

$ 159.00

High borosilicate Glass material, corrosion resistance and can withstand large thermal Impact, vacuum negative pressure of 0.095MPa, Speed range 50~ 500rpm, suitable for material synthesis and distillation recovery.

$ 3849.00

Can reduce the contact resistance of 35~ 95% and temperature rise of 35~ 85%, high temperature resistance up to 200 ℃, with anti-oxidation, anti-corrosion performance, suitable for a variety of metal connections, improve safety and stability.

$ 136.00

Four-terminal Resistance Measuring method is used to eliminate the influence of wire resistance, test Precision 0.1% reading + 2 words, Measurement speed is fast 32 times/second, with perfect sorting function, alarm value can be set for percentage sorting, strong anti-interference ability.

$ 251.00

Can reduce the contact resistance of 35~ 95%, reduce the temperature rise of 35~ 85%, high temperature resistance of 200 ℃, with anti-oxidation, anti-corrosion performance, suitable for different metal connections, improve electrical connection Stability.

$ 87.00

Three sets of samples can be tested simultaneously, supporting two standard methods of no presser foot and presser foot, adjustable fixture movement amplitude, frequency conversion speed regulation, and automatic counting and shutdown functions after reaching the set number of times.

$ 7335.00

Temperature range -40 ℃ to + 150 ℃, the temperature conversion time is only 10 seconds, using PID full digital automatic Control system, can quickly detect the material in the extremely high temperature and low temperature continuous environment resistance and thermal expansion and contraction changes.

$ 17303.00

Using PT100 platinum resistance imported from Japan to measure temperature, the fully enclosed Compressor has low operating noise and high cooling efficiency, Temperature Fluctuation +/- 0.1 ℃, supports internal and external circulation and 4L/min pump Flow rate, stable and reliable temperature control.

$ 948.00

Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.

$ 4222.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.