Measurement range covers 0~ 5mg/L residual chlorine total chlorine and 0~ 10mg/L chlorine dioxide, support 100 measurements, suitable for water quality testing, easy and fast operation.
Simultaneous measurement of residual chlorine, chlorine dioxide, total chlorine and other five paraMeters, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and high Reliability integrated circuit to ensure long-term stable work.
Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.
8Nm Narrowband Interference filter and LED Illuminant, wavelength accuracy +/- 1nm, support residual chlorine and total chlorine 0.00-5 mg/L Measurement range, built-in reaction Timer and 50 sets of Data storage, with IP67 waterproof performance.
Measurement range 0~ 5mg/L, can carry out 100 measurements, suitable for a variety of water quality analysis instruments, easy to operate quickly detect residual chlorine and total chlorine content.
With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.
LED Illuminant provides stable detection performance, supports CAL CheckTM calibrated verification, Measurement range 0-500ppb, accuracy +/- 5ppb, with reference to USEPA method 330.5 and DPD method for ultra-low concentration total chlorine detection.
The DPD method reacts with chlorine to pRoduce a pink color. Measurement range is 0.00 to 5.00 mg/L, providing 100 tests to ensure fast and accurate Colorimetric analysis.
Measurement accuracy is ensured by 515nm wavelength Illuminant, Measurement range 0.02-3 mg/L, support 200 sets of Data storage and IP65 protection, lithium battery power supply is convenient for field use.
Optical inspection system using cold Illuminant narrowband interference, Optical inspection stability is less than 0.002A/20min, can save 20 standard Linear dispersion and 199 measured values, IP65 protection design to adapt to the field environment.
Measurement range of 0.00 to 5.00 mg/L, accuracy +/- 0.03 mg/L, built-in reaction Timer and Automatic calibration verification function to ensure measurement conformity.
Using imported cold light source and TMB photometry, the detection limit reaches 0.1mg/L, supports continuous measurement and standard Measurement mode, built-in 4000 data storage and a variety of transmission interfaces.
Measurement accuracy is ensured by 515nm LED Illuminant, intelligent end point determination supports automatic reading, IP65 Protection Rating adapts to a variety of environments, and built-in 200 sets of Data storage meet detection needs.
Using 515nm and 420nm dual LED Illuminant, equipped with high definition color LCD screen, built-in multiple Measuring methods, support automatic reading and Data storage functions, IP65 Protection Rating to ensure outdoor use Reliability.
Using BNC connector design, equipped with 60mL calibrated solution and residual chlorine regulator, replaceable membrane to extend service life, suitable for water quality monitoring.