Carton Slip Angle Measuring Instrument

The cardboard box slip angle tester simulates stacked conditions by tilting a platform to measure the critical angle at which the box begins to slide. This data is used to evaluate the surface friction properties of cardboard boxes, guiding warehouse stacking and anti-slip measures during transportation to prevent packaging collapse.
Selection
When selecting, pay attention to the tilt table size matching the specifications of the carton to be tested, and the accuracy of the angle sensor should reach 0.1°. The platform should be equipped with anti-slip baffles. Prioritize models with a digital level to ensure test repeatability. Consider the influence of temperature and humidity in the test environment on the results.

Terms

Instruments

Measurement range 2T, pressure speed 5~ 300mm/min stepless adjustable, support 7-inch Touchscreen real-time display of compressive Linear dispersion, suitable for a variety of carton strength detection.

$ 3785.00

Using injection defined bottom surface method for measurement, the funnel outlet has a diaMeter of Φ 5mm and a taper of 60 ° +/- 0.5 °, which can accurately measure the acute angle between the inclined surface of dust accumulation and the horizontal one.

$ 525.00

Single arm double column structure equipped with hydraulic buffer device, drop height 400-1500mm adjustable and accuracy of +/- 10mm, support face angle full angle drop test and have electric reset function, maximum load weight 100kg to ensure test Stability.

$ 2612.00

Measurement accuracy of +/- 0.1 ° and angle resolution of 0.001 ° with SONY high-speed industrial-grade chip and 0.7-4 zoom Microscope head. Measurement modes such as seat drop method, forward angle and backward angle are supported, and 2 million test records can be stored.

$ 2897.00

CCD camera system to achieve 1280 × 1024 resolution image analysis, support 0~ 180 ° contact angle and 0~ 400mN/m surface tension measurement, with dynamic contact angle analysis and solid surface energy estimation function.

$ 4077.00

Double step motor control titration system, accuracy of 0.01 μl, equipped with 0.7-4 times continuous zoom Microscope and dense LED backlight Illuminant, support dynamic test forward angle, backward angle and surface tension measurement by hanging drop method, test range 0-180 °.

$ 9223.00

With 20 °/60 °/85 ° three-angle simultaneous measurement, measurement range of 20 ° up to 0-2000Gs, 2.4-inch color screen and 3000mAh lithium battery, support data storage and Bluetooth connection, Stability is high and portable and durable.

$ 554.00

The single-arm double-column structure is equipped with a hydraulic buffer device, with a drop height error of no more than +/- 10mm and an angle error of less than 5 °. It supports seven-speed height adjustment and face corner drop mode, with a maximum load of 65kg and an electric lifting function.

$ 2612.00

The static drop method, droplet method and inclined plate method are used for measurement of dynamic contact angle, with automatic sampling, automatic surface tension analysis and automatic contact angle analysis functions. Degree of automation is high and Measurement accuracy is high.

$ 6205.00

The instrument's observation angle is continuously adjustable from 0.2 ° to 2.0 °, the incident angle covers +/- 0 ° to +/- 20 °, and the Measurement range is 0~ 3000 mcd • lx-1. It uses silicon diode Detectors and standard A Illuminants to ensure measurement accuracy.

$ 6386.00

Observation angle 0.2 °~ 2.0 ° continuously adjustable, incident angle -40 °~ + 40 ° adjustable, using silicon diode Detector and lithium battery power supply, support continuous work for more than 30 hours, suitable for indoor and outdoor measurement.

$ 6386.00

The injection limited bottom surface method is used to directly measure the angle of repose, the funnel taper is 60 ° +/- 0.5 °, and the outflow diaMeter is 5mm, which is suitable for powder flowability analysis of different particle sizes and shapes.

$ 545.00

The instrument supports two tilt angle tests of 10 ° and 30 °, and can measure key paraMeters such as slip, re-leakage and leakage, and simulate real use scenarios to evaluate instantaneous absorption capacity.

$ 440.00

Baseline and droplet contours are automatically recognized by machine vision, and contact angles are calculated based on Laplace equation quadratic Linear dispersion fitting. Measurement range is 0-180 °, accuracy is 0.1 °, and dynamic contact angle measurement and surface energy calculation are supported.

$ 3462.00

With Vacuum chuck function, drop height 300~ 2000mm adjustable, support 0 °, 45 °, 90 ° multi-angle drop, with Acceleration and speed measurement, can accurately control the impact site.

$ 779.00

Articles