Acrylonitrile alarm

Acrylonitrile alarms utilize electrochemical or semiconductor sensors to detect the concentration of acrylonitrile in the air, emitting audible and visual alarms when the concentration exceeds a preset threshold. They are used for leak monitoring in locations such as chemical plants and plastic production facilities to ensure personnel safety.
Selection
When selecting, consider the detection range covering on-site concentrations, explosion-proof ratings matching the environment, sensor lifespan, and calibration cycles. Ensure the response time meets safety requirements, verify product certifications and protection ratings, and assess the compatibility of the installation method with the site conditions.

Terms

Standards

Instruments

Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA/RS485/switch output, can be operated by remote control without opening the lid, with explosion-proof protection structure.

$ 461.00

Support 4-20mA and RS485 signal input, compatible with two-wire and three-wire devices, provide 6 passive switching control ports, with two-level alarm setting and alarm record query function, temperature operation range 0-40 ℃.

$ 183.00

Support 8 channels of 4-20mA signal input, can store 20,000 alarm records, with two-level alarm settings and relay output, suitable for multi-point centralized control to prevent explosions and fire accidents.

$ 212.00

Support 16 4-20mA signal input, 4.3 inch color screen display, can store 20000 alarm records, with two-level alarm and four sets of relay output, suitable for multi-point centralized control of Gas detection.

$ 259.00

Supports 4-20mA signal input, compatible with two-wire and three-wire devices, provides 6 passive switches and RS485 interfaces, with two-level alarm settings, operating temperature 0-40 ℃, suitable for gas safety detection.

$ 212.00

Support 32 Detector access, using 4-20mA signal transmission, with two-level alarm settings and 20,000 records Storage capacity, through the relay drive peripherals to ensure safety protection.

$ 401.00

Support 4-20mA signal input and RS485 upload, with 2-level alarm and 2 relay output, compatible with two-wire and three-wire equipment, fast response speed and high measurement accuracy, suitable for a variety of Gas detection scenarios.

$ 140.00

With +/- 1% measurement error and 0.005N.m Graduation, support upper and lower limit setting automatic alarm, can store 99 sets of data and calculate statistical values, with peak hold and unit automatic conversion function.

$ 336.00

Two-channel split-line design supports multi-point centralized control, adopts 4-20mA signal input and two-level alarm setting, with relay output drive peripheral function, Operating temperature range -10~ 50 ℃ to ensure stable operation.

$ 140.00

Using Semiconductor Sensor, Response Time T90 is less than 10 seconds, detecting a variety of combustible gases, range 0~ 50% LEL, with sound and light alarm and LED large screen display.

$ 141.00

Support 4-20mA/RS485 signal input, compatible with two-wire and three-wire devices, providing up to 6 passive switching quantities, two-level alarm can be freely set, suitable for gas safety detection.

$ 259.00

Two-channel split design supports multi-point centralized control, with 4-20mA signal input and two-level alarm settings, microprocessor to ensure accurate monitoring, relay output can drive external equipment linkage, Operating temperature range -10~ 50 ℃.

$ 140.00

High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.

$ 157.00

The equipment range 0~ 30% vol, resolution 0.1%, support three alarm and temperature measurement, high-brightness backlight for low-light environment use, can set the lock machine password to enhance security.

$ 155.00

With +/- 1% measurement accuracy and 0.05N.m Graduation, support upper and lower limit deviation setting automatic alarm, can store 99 sets of data and automatically calculate statistical values, three units are automatically exchanged, with backlight display and automatic shutdown function.

$ 346.00