Package Drop Tester

The luggage drop test machine simulates the impact of drops during transportation by lifting the luggage to a set height and releasing it via a lifting mechanism. It is used to test the structural strength, stitching durability, and accessory endurance of luggage, suitcases, backpacks, and other products for quality verification.
Selection
When selecting, consider matching the maximum load capacity and sample size to the testing requirements, ensure the drop height adjustment range covers standard specifications, and ensure the impact panel material is flat and hard. The control system should include height calibration and drop count functions, and safety protection devices must be complete and reliable.

Terms

Standards

Instruments

Single arm double column structure equipped with hydraulic buffer device, drop height 400-1500mm adjustable and accuracy of +/- 10mm, support face angle full angle drop test and have electric reset function, maximum load weight 100kg to ensure test Stability.

$ 2612.00

With Vacuum chuck function, drop height 300~ 2000mm adjustable, support 0 °, 45 °, 90 ° multi-angle drop, with Acceleration and speed measurement, can accurately control the impact site.

$ 779.00

Adopting a single-arm double-column structure, equipped with a hydraulic buffer device to improve service life and stability, with a drop height range of 400 to 1500mm, it can test up to 80kg specimens, meeting a variety of standard testing requirements.

$ 1747.00

Adopting double column guide and hydraulic buffer system, the drop height range can be set from 0 to 2000mm, the maximum load is 300kg, and it supports all-round drop testing of edge angles and has upper and lower induction protection devices.

$ 10933.00

The equipment is designed with double rollers, with a test load of 5kg, a drop height of 500 + 1000mm, and a rotation speed of 5-20 times/minute to meet the needs of continuous rotary drop testing.

$ 1174.00

The equipment can perform continuous rotary drop test, drop height up to 1000mm, Test speed 5-20 times/min, suitable for Reliability verification of small electronic pRoducts.

$ 1053.00

The single-arm double-column structure is used to realize the free drop of the face corner, and the height tracking system is equipped to make the drop height error not exceed 2%. The buffer device improves the service life and safety of the equipment.

$ 1886.00

It can simultaneously test two devices, with a maximum load of 2kg and a drop height of 60 to 150mm. It uses pneumatic components and PLC control to achieve high-speed consistent testing, and has automatic stop and count functions.

$ 1380.00

Can test 300~ 1500mm drop height, bearing 100kg load, double wing structure to ensure that the drop plane error is less than 1 °, suitable for all kinds of Encasement box testing.

$ 2720.00

The instrument employs the principle of heavy hammer impact, with a drop height adjustable within the range of 1000 ± 5 mm and a hammer mass of 500 ± 1 grams, designed for the precise determination of a material's puncture resistance.

$ 425.00

Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.

$ 1719.00

The single-arm double-column structure is equipped with a hydraulic buffer device, with a drop height error of no more than +/- 10mm and an angle error of less than 5 °. It supports seven-speed height adjustment and face corner drop mode, with a maximum load of 65kg and an electric lifting function.

$ 2612.00

Pneumatic fixture is used to protect the pRoduct from deformation, and a protective box is equipped to prevent the specimen from rushing out. The drop height is adjustable from 300-1500mm, the test load is 2kg, and the height is displayed by High Accuracy steel ruler and digital display Meter.

$ 1414.00

The single-arm double-column structure is equipped with an electric lifting device, with a drop height range of 300-1500mm, a test load of 0-80kg, and a buffer device to improve service life and stability. The height error does not exceed 2%.

$ 1848.00

The drop height is 300~ 1500mm, the test load is 100Kg, the maximum size of the specimen is 1000 * 800 * 1000mm, the baseplate size is 1700 * 1200mm, and the plane error is less than 1 degree.

$ 2720.00

Articles

Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.