Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.
Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.
Humidity measurement range -10~ 60 ℃ and 10~ 95% RH, Sampling time 0.4 seconds, Automatic recording MAX Maximum, MIN Minimum and Final Measured value, Built-in Sensor and support USB data output.
Measurement range, Humidity 10.0-95% RH, Temperature 0.0-60 ℃. High accuracy with film polymer capacitive Sensor. Battery error prevention system for measurement Reliability.
Using External Sensor, Humidity accuracy of +/- 0.2 ℃ and +/- 2.5% RH respectively, Humidity Response Time as fast as 15 seconds. With Bluetooth wireless setting and download, weatherproof shell, support mobile end real-time viewing and data sharing.
Using imported Sensor and TMHM equilibrating Conditioning method, temperature control accuracy of +/- 0.5 ℃, humidity control accuracy of +/- 3% RH, with independent temperature limit alarm system to ensure experimental safety.
Temperature range -10~ 70 ℃, Humidity Control Range 40~ 95% RH, using imported Sensor and microcomputer controller, with independent temperature limit alarm system, can be equipped with RS485 interface and test hole.
Imported Infrared Sensor, CO2 concentration control accuracy of +/- 0.1%, restore the set concentration within 3 minutes after opening the door; equipped with high temperature heating and humidity sterilizing system, can completely eliminate microbial pollution, circulating fan speed automatic adjustment to avoid sample volatilization.
Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, 3 minutes to quickly restore the set concentration; equipped with high temperature heating and humidity sterilizing function, effectively eliminate microbial contamination, circulating fan automatic speed control to protect the sample.
Using Infrared Sensor to control CO2 concentration, it can be restored to 5% set value within 3 minutes after opening the door for 30 seconds; equipped with 90 ℃ high temperature heating and humidity sterilizing system, fully sterilized for 18 hours; HEPA Filter makes the air mass in the box reach 100 clean level.
Using Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, equipped with high temperature heating and humidity sterilizing function, CO2 concentration is restored within 3 minutes after opening the door, and the circulating fan automatically adjusts the speed to avoid sample volatilization.
Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.
Adopt TMHM equilibrating Conditioning method, temperature control accuracy up to +/- 0.5 ℃, equipped with imported Humidity Sensor and independent temperature limit alarm system, 25mm test hole on the left for easy operation.
Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.