NO Sensor

NO sensors detect nitric oxide concentration through electrochemical or semiconductor principles. Electrochemical types utilize the oxidation-reduction reaction of gases at electrodes to generate current, while semiconductor types rely on gas adsorption to alter material resistance. They are used in environmental monitoring, industrial safety, automotive exhaust detection, and other fields.
Selection
When selecting, consider that the detection range must cover application requirements. Electrochemical types are suitable for low-concentration detection, while semiconductor types respond quickly but are prone to interference. Pay attention to matching the operating temperature with the field conditions, verify cross-interference data, and note that service life and calibration cycles impact maintenance costs.

Terms

Standards

Instruments

Electrochemical sensor to detect oxygen, range 0~ 25% VOL, Sensor life up to 5 years, Response Time ≤ 15 seconds, with sound and light alarm and continuous 90 hours of work ability.

$ 270.00

Platinum Sensor ensures measurement Stability, built-in temperature sensor automatically senses sample temperature, ElectRode constant K = 1, Operating temperature range 0~ 60 ℃, suitable for a variety of instruments.

$ 106.00

Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Conductivity Detector cell constant K = 1, Low noise Shielding line design effectively reduces signal interference.

$ 140.00

Using Piezoelectric Ceramic Shear Sensor, Acceleration Measurement range 0.1~ 199.9m/s, Speed Measurement range 0.1~ 199.9mm/s, with automatic range switching and backlight display function.

$ 239.00

Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, resolution up to 0.1 ℃ and 1% RH.

$ 112.00

Using split Sensor design, Temperature Measurement range -10~ 50 ℃, Humidity Measurement range 5~ 98% RH, support ℃/F unit conversion, equipped with 9V battery power supply.

$ 119.00

The Piezoelectric Ceramic Shear Sensor can simultaneously measure Acceleration, Speed and Displacement, Acceleration Measurement range 0.1~ 199.9 m/s ², with automatic switching range and backlight display function.

$ 276.00

Using Piezoelectric Ceramic Shear Sensor, Acceleration Measurement range 0.1~ 199.9m/s ², Frequency range 10Hz~ 1KHz, with automatic switching range and backlight display function.

$ 308.00

Using split Sensor design, the temperature range covers -50~ 70 ℃, Humidity Measurement range 20%~ 99% RH, supports ℃/F unit conversion, which is convenient for indoor and outdoor environment monitoring.

$ 81.00

Platinum Sensor ensures measurement Stability, built-in temperature sensor automatically senses sample temperature, ElectRode constant K = 1, Operating temperature range 0~ 60 ℃.

$ 106.00

Simultaneous monitoring of four gases, Electrochemical sensor, Response Time less than 50 seconds, Operating temperature range -10~ 50 ℃, with sound and light alarm function.

$ 288.00

Electrochemical sensor is used to detect CO gas, with a range of 1~ 1000ppm, a resolution of 1ppm, and a Response Time of less than 60 seconds.

$ 104.00

Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.

$ 294.00

Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.

$ 99.00

Using Platinum Sensor to Ensure Measurement Stability, ElectRode Constant K = 10, Built-in temperature sensor to achieve automatic temperature compensation, Operating temperature range 0~ 60 ℃.

$ 106.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Dart impact tester measures the toughness of packaging film.
The dart impact test evaluates the material's resistance to damage under dynamic impact, i.e., its toughness, by allowing a dart to fall freely and strike the packaging film. During the test, different impact energies are simulated by adjusting the weight of the dart or the drop height, and sensors are used to detect whether the film ruptures.
Electronic universal testing machine measures film tensile strength.
This article introduces the method of measuring the tensile strength of thin films using an electronic universal testing machine. During the test, the machine applies tensile force to the film sample, records the maximum tensile force and displacement through sensors, and then calculates the tensile strength using a formula.
Selection of Temperature and Humidity Meters: Sensor Accuracy and Response Time
When selecting a temperature and humidity meter, sensor accuracy and response time are key parameters. Accuracy refers to how close the measured value is to the actual value, typically expressed as an allowable error, with high-precision sensors being more costly.
In the selection of illuminance meters, sensor type and measurement range are key considerations.
This article introduces the key points for selecting sensor types and measurement ranges when choosing an illuminometer.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.