Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Using D/8 ° illumination and integrating sphere design, the repeability accuracy Delta E * ab within 0.04, Inter-Agreement Delta E * ab 0.2, supports a variety of color difference formulas and Illuminant modes, and the measurement time is only 1.5 seconds.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
The colony contrast is clear by using ring lamp side-shot illumination, equipped with three-digit display and counting probe pen, the counter capacity is 0-999, and it has a 30-day charging standby function, which can reduce the experimental labor intensity.
Adopt D/8 ° illumination and Φ 58mm integrating ball, repeability accuracy Delta E * ab within 0.04, support liquid, powder and other sample testing, equipped with 3.5 inch capacitive Touchscreen and large capacity storage.
It has the function of switching between light and dark field of view, supports 40X-1600X magnification range, and uses oblique illumination to make the outline of the sample clearly visible. It is suitable for morphological observation of unstained biological samples.
D/8 illumination observation conditions, measurement time 20ms, 0.5mm distance from the sample non-contact measurement, built-in black and white calibrate and ETC real-time calibrate technology to ensure high repeability and accuracy.
The three-sided lighting design ensures no dead angle lighting, the six-level adjustable illumination 0~ 25000Lx meets different needs, the mirror stainless steel liner is easy to clean, and supports 99-cycle programming to achieve complex experimental processes.
With three-sided lighting and six-level adjustable illumination 0~ 25000LX, Temperature range 4~ 50 ℃, can simulate day and night temperature Humidity changes, support 30 sets of program settings and independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, temperature fluctuation is only +/- 0.5 ℃.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, support 10-1000PPhm ozone concentration range, Temperature Fluctuation control within +/- 0.5 ℃.
The heating wire is used to achieve rapid heating, the temperature fluctuation is only +/- 0.5 ℃, equipped with 360 degree swirl/spin sample holder and imported concentration Analyzer, supports dynamic static test mode, and meets a variety of test needs.
Using heating wire and PT100 temperature transducer, Temperature Fluctuation +/- 0.5 ℃, support 0~ 999H light time setting, 360 degree swirl/spin sample holder and imported concentration Analyzer to ensure test accuracy.
Using refractive index Measurement principle, automatic temperature compensation 0-40 ℃, Measurement time of about 1.5 seconds, only 100 μ L sample volume, support PSU, ppt and specific gravity three unit conversion, stainless steel sample Chamber corrosion resistance.
Using electric heating wire to achieve rapid and uniform heating, equipped with 360-degree swirl/spin sample holder and 12-16mm/s gas flow rate, support 0-9999 hours time setting, with leakage overtemperature multiple safety protection.