Using 40KHz Frequency and 640KHz crystal time base circuit, the weight is only 50 grams and easy to carry, which can accurately detect air leakage sources in various environments.
Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.
Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using rectangular platinum plating ElectRode, drop time interval of 30 +/- 1 seconds, with automatic cut-off protection function.
Touchscreen control, automatic constant pressure gas to ensure that the experiment in the preset vacuum, Vacuum Level range of 0~ -90KPa, a key operation automatically end the test, stable and durable performance.
Using rectangular platinum ElectRode, the ElectRode force is 1.0N +/- 0.05N, the test voltage is adjustable from 100 to 600V, and the voltage drop does not exceed 10% when the short-circuit current is 1.0 +/- 0.1A. The dripping device can accurately control the dripping volume and time interval.
The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.
Support 0 °, 10 °, 30 ° multi-angle test, equipped with 250mL liquid discharge funnel and 500mL measuringflask, can meet the needs of sanitary napkins and diapers at the same time, such as slippery penetration, re-penetration and other penetration performance measurement.
The 0-16bar positive pressure method is used to test, which avoids the low pressure limit. The sealing situation can be judged by observing the leakage or pressure drop by inflation and pressure. Sensitivity is high and the reading is accurate.
Adopting stainless steel frame and 10mm float plate Glass structure, the gas leakage rate is less than 0.5% of the box volume at 1000 Pa per minute, and the surface is smooth and clean without adsorption, ensuring accurate and reliable test data.
Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.
Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.
Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.
Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.
Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.
Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.