Atomic Flame SpectroPhotoMeter

The atomic flame spectrophotometer quantifies the content of elements by atomizing samples in a flame and measuring the absorption intensity of light at specific wavelengths. It is used to detect the concentration of metal elements, such as lead and copper, in materials like coatings and inks.
Selection
When selecting, consider the matching of the detection element range with the instrument's wavelength, ensure sample processing is compatible with the nebulizer, and use a flame type suitable for common acetylene-air configurations. Pay attention to the detection limit meeting industry standards, maintenance costs and gas consumption, and ensure that operational training is provided accordingly.

Terms

Standards

Instruments

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.

$ 2655.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.

$ 2655.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.

$ 2171.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, Stability relative change within 15 seconds ≤ 2%.

$ 3543.00

Using concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, Response Time is less than 8 seconds, Stability relative change within 15 seconds does not exceed 2%.

$ 3543.00

Using concave Holographic grating design, Light spectrum is pure, narrow passband, Sensitivity is high, linearity is better; Support any combination of five elements while direct reading measurement, automatic ignition and flameout protection function to ensure safety.

$ 3543.00

Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, narrow passband, high Sensitivity, good linearity; supports any combination of five elements for direct reading measurement, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.

$ 4430.00

Concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, with automatic ignition and flameout protection function.

$ 2655.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.

$ 820.00

1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.

$ 1219.00

The equipment adopts stainless steel structure to resist corrosion, equipped with automatic ignition and Timing function, combustion time 0~ 99.99 seconds, gas lamp Nozzle inner diaMeter 9.5mm, to ensure accurate and reliable testing.

$ 670.00

Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.

$ 946.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.