ASTM Viscosity Cup

The ASTM viscosity cup determines viscosity by measuring the time it takes for a fluid to flow out through a standard orifice. The principle is based on the inverse relationship between the flow rate of the fluid under gravity and its viscosity. It is used for rapid viscosity testing of liquids such as paints and inks to ensure process stability.
Selection
When selecting an ASTM viscosity cup, it is essential to match the viscosity range of the liquid being tested, with models categorized based on standard orifice sizes. Consider the material's corrosion resistance, as stainless steel is suitable for most liquids. Verify that the product complies with ASTM standard specifications to ensure measurement consistency.

Terms

Instruments

Outflow aperture 1.9mm, viscosity measurement range of 10~ 35cSt, aluminum alloy Cup body and stainless steel pore structure durable, in line with ASTM D1200 standard.

$ 167.00

Using stainless steel aperture 5.20mm, viscosity measurement range of 200~ 1200cSt, aluminum alloy Cup body sturdy and durable, in line with ASTM D1200 standard, suitable for laboratory accurate measurement of fluid viscosity.

$ 170.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

With double-decked anodic oxidation aluminum structure, it supports dual functions of chilling down and heating, and can precisely control the temperature of the viscosity Cup to the required range, which is suitable for DIN and ASTM standard Cup types.

$ 1202.00

Manufactured according to ASTM D 2162 and fully traceable to national standards, it provides rotor calibrated viscosity of 17.53mPa · s at 20 ° C and 14.26mPa · s at 25 ° C, and is compatible with a wide range of test equipment.

$ 471.00

In accordance with ASTM D 4212 standard design, the diaMeter of the flow hole is 2mm, and the viscosity range is 5~ 60cSt. It can quickly determine the liquid viscosity in the pRoduction site or laboratory, and is easy to operate.

$ 115.00

The stainless steel material is durable, the inner wall of the Cup body is smooth to ensure stable Flow velocity, the diaMeter of the flow hole is 2mm, and the viscosity range of 70cSt can be measured. Precision machining ensures measurement accuracy.

$ 190.00

Using titanium anodic oxidation aluminum Cup body and stainless steel filter, 3.4mm pore size design, viscosity measurement range 49-220cSt, Cup mouth deep groove anti-overflow, unique serial number traceability mass.

$ 500.00

Aperture 3.76mm, viscosity range 100-800cSt, outflow time 20-80 seconds, in line with ASTM standard design, suitable for rapid determination of medium viscosity pRoducts.

$ 115.00

5.28Mm flow hole diaMeter, viscosity range of 400~ 1800cSt, flow time of 20~ 80 seconds, in line with ASTM standard design, can be quickly measured in the pRoduction site or laboratory liquid viscosity.

$ 115.00

Aperture 5.2mm, viscosity measurement range 200-1200cSt, Cup mouth design anti-spill groove, unique serial number logo, matching special bracket to improve test Stability.

$ 497.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the aperture is 3.40mm, the viscosity measurement range is 49~ 220cSt, and the outflow time is 25~ 105 seconds.

$ 130.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Xenon lamp aging test chamber for testing the weather resistance of exterior wall coatings.
Xenon lamp aging test chambers accelerate the aging of exterior wall coatings by simulating environmental conditions such as sunlight, temperature, humidity, and rainfall, to evaluate their weather resistance. The tests are conducted in accordance with standards such as ISO and ASTM, controlling key parameters such as irradiance, temperature, humidity, and spray cycles.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.