Non-contact Moisture Analyzer

Non-contact moisture analyzers use microwave or infrared technology to penetrate materials and calculate moisture content based on differences in the absorption characteristics of electromagnetic waves by water. They are used for real-time monitoring of moisture in materials such as coatings and paper on production lines, avoiding the damage caused by sampling.
Selection
Select materials based on their wave transmission properties, such as using microwaves for paper and infrared for films. The measurement range should cover common moisture levels, with a response speed that matches the production line's pace. Environmental interference resistance must meet workshop conditions, and calibration functions should ensure long-term stability.

Terms

Standards

Instruments

D/8 standard non-contact test, measurement distance 3.0mm, the fastest 0.2 seconds to complete the measurement, support a variety of Color Space and Illuminant, suitable for automatic pRoduction line accurate Color quality control.

$ 8109.00

Using 45/0 ring lighting and concave grating spectroscopy technology, the measurement diaMeter is Φ 20mm, the non-contact measurement distance is 7.5mm, and the chromatic value Repeatability is within 0.03. Color difference formula and chroma index analysis are supported.

$ 8109.00

Adopt 45/0 structure, measurement Repeatability dE * ab ≤ 0.02, Inter-instrument Agreement dE * ab ≤ 0.25, support non-contact detection, waterproof and dustproof IP66, multiple communication interfaces, LED Illuminant long life.

$ 3946.00

Adopt 45/0 ° ring illumination and concave grating spectroscopy, measurement wavelength 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination, support a variety of Measurement modes and camera positioning.

$ 8109.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

Using 45/0 ring lighting and concave grating spectroscopy technology, measurement Wavelength range 400~ 700nm, non-contact distance 7.5mm, avoid sample contamination and damage, support a variety of Measurement modes and camera positioning.

$ 7464.00

Optical inspection structure of 45/0 °, non-contact distance of 7.5mm, measurement wavelength of 400-700nm, avoid sample contamination and damage, support a variety of Measurement modes and High Accuracy Color Analysis.

$ 7464.00

Measurement range 200-20000 rpm, accuracy of +/- (1 × 10 × reading + 1) rpm, support non-contact speed measurement and steering determination function.

$ 198.00

The non-contact grating optocoupler Sensor is used to automatically collect data, with a nominal kinetic energy of 2.207J, supports automatic calculation of intensity and voice broadcast, and has a built-in steel anvil calibration function to improve detection efficiency and accuracy.

$ 369.00

Non-contact automatic whiteboard calibration technology, Inter-instrument Agreement Delta E * 00 < 0.2, high measurement Stability, supports more than 30 Color indicators and 28 kinds of observation Illuminants, compact and easy to carry.

$ 332.00

Non-contact measurement distance 7.5mm +/- 3mm fluctuation is still accurate, the measurement time is only 20ms, built-in auto calibration and Gloss compensation technology to ensure accurate and reliable Color data.

$ 12068.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Using 45/0 ring illumination and concave grating spectroscopy technology, the measurement diaMeter is 20mm, and the non-contact distance is 7.5mm. With 256 pixel dual array CMOS sensor, Wavelength range 400~ 700nm, chromatic value Repeatability Delta E * ab 0.05, supports a variety of Color space and color difference analysis.

$ 7464.00

Repeatability less than or equal to 0.05, display accuracy 0.01, non-contact automatic whiteboard calibration and integrating ball dual optical path design, Type-C interface can be continuously tested 12,000 times when fully charged.

$ 393.00

Repeatability Delta E * ab within 0.1, Measurement time of about 1.0 seconds; Non-contact automatic whiteboard calibration to avoid dirt, integrating ball double light path design to ensure stability, lightweight and portable can be continuously tested 12,000 times.

$ 234.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Moisture Analyzer Combined with Karl Fischer Method for Measuring Moisture Content in Resin Solvents.
This article introduces the use of the Karl Fischer method in conjunction with a moisture analyzer to measure the water content in resin solvents.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Selection Basis for Karl Fischer Titration: Volumetric vs. Coulometric Methods
There are two methods for Karl Fischer moisture titrators: volumetric and coulometric. The volumetric method calculates moisture by measuring the volume of a reagent with a known concentration that is consumed, making it suitable for samples with higher moisture content, such as those in the range of a few thousandths or more.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.