High-temp Infrared PyroMeter

A high-temperature thermometer gun receives heat radiation from the surface of an object through an infrared sensor, converts it into an electrical signal, and displays the temperature value. It is used to measure the surface temperature of high-temperature equipment such as furnaces and ovens, and to monitor heat treatment processes in metal processing and ceramic firing.
Selection
When selecting, ensure the measurement range covers actual needs, pay attention to the distance coefficient ratio to guarantee measurement accuracy, check the response time to match dynamic temperature measurement scenarios, consider the emissivity adjustment function to adapt to different materials, and inspect the protection rating to suit industrial environments.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Imported Infrared Sensor, CO2 concentration recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes, equipped with HEPA high-efficiency Filter, with door temperature heating system and automatic wind speed adjustment function.

$ 8955.00

Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.

$ 307.00

Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.

$ 153.00

Stainless steel enclosure guarantees durability, built-in 10KΩ temperature sensor Response fast, Measurement range 0-110 ℃, Compact design for plug-in installation, Ensure Reliability of temperature measurement.

$ 105.00

Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.

$ 2368.00

Stainless steel shell adapts to complex environment, built-in 10KΩ Sensor Response, Measurement range 0-110 ℃, compact design for easy plug-in installation, support BNC interface for easy connection.

$ 105.00

Imported Infrared Sensor, CO2 concentration control accuracy of +/- 0.1%, restore the set concentration within 3 minutes after opening the door; equipped with high temperature heating and humidity sterilizing system, can completely eliminate microbial pollution, circulating fan speed automatic adjustment to avoid sample volatilization.

$ 4122.00

Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, 3 minutes to quickly restore the set concentration; equipped with high temperature heating and humidity sterilizing function, effectively eliminate microbial contamination, circulating fan automatic speed control to protect the sample.

$ 4911.00

Using Infrared Sensor to control CO2 concentration, it can be restored to 5% set value within 3 minutes after opening the door for 30 seconds; equipped with 90 ℃ high temperature heating and humidity sterilizing system, fully sterilized for 18 hours; HEPA Filter makes the air mass in the box reach 100 clean level.

$ 5815.00

Using Infrared Sensor to achieve CO2 concentration +/- 0.1% control accuracy, equipped with high temperature heating and humidity sterilizing function, CO2 concentration is restored within 3 minutes after opening the door, and the circulating fan automatically adjusts the speed to avoid sample volatilization.

$ 5503.00

Using infrared CO2 Sensor, concentration recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes. Equipped with HEPA high-efficiency Filter, the air mass in the box can reach 100 clean levels, and the circulating fan speed is automatically controlled to avoid sample volatilization.

$ 5110.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.

$ 2494.00

Infrared Sensor, CO2 recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes, equipped with HEPA high-efficiency Filter, the air mass in the box can reach 100 clean levels, and the circulating fan speed is automatically controlled to avoid sample volatilization.

$ 3728.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.