Metal Thickness Gauge

A metal thickness gauge measures the change in distance between the metal surface and the probe through electromagnetic induction or eddy current effects, converting it into a thickness value for display. It is used to detect the thickness of coatings, platings, or substrates, ensuring that products meet specification requirements in quality inspection and process control.
Selection
When selecting a metal thickness gauge, consider the magnetic permeability of the material being measured, the shape of the substrate, and the thickness range. Choose between contact or non-contact probes based on the environment, ensure the accuracy meets the application requirements, and refer to ease of operation and calibration stability.

Terms

Standards

Instruments

Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.

$ 320.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Measurement range 0~ 1500 microns, error +/- 1%, support magnetic Induction principle, IP65 Protection Rating and 250 reading storage, suitable for ferrous metal substrate nonmagnetic coating environment.

$ 890.00

Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.

$ 219.00

Detachable built-in Probe design, support one-handed operation, Measurement range 0~ 13mm, accuracy +/- 3%, suitable for Coating thickness detection of different metal substrates.

$ 932.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250 microns, equipped with thermal printer can print test data in real time, suitable for a variety of nonmagnetic metal substrate insulation coating thickness detection.

$ 219.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 1250 microns, minimum substrate 0.3mm, with continuous testing, Data storage and a variety of calibrating modes, easy operation and high accuracy.

$ 364.00

The eddy Current principle is used for measurement of nonconductive coatings on non-ferrous metal substrates, with a thickness range of 0~ 625μm and an error of +/- 3%. It has IP65 Protection Rating and fast measurement capabilities of more than 60 readings per minute.

$ 1338.00

Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.

$ 323.00

Measurement range 0.65-400 mm, the highest accuracy is +/- 0.04mm, supports four measurement modes, Data storage 3000 groups, high-speed measurement up to 10 times/second, suitable for a variety of metal materials.

$ 835.00

Measurement range 0.75-400 mm, accuracy +/- (0.1 + 1% H) mm, support standard and ultra-thin mode, built-in speed of sound of various materials, portable design for on-site inspection.

$ 173.00

With 0.1mm high resolution and +/- 0.5% H accuracy, support single point 4 times per second and scan 10 times per second measurement frequency, adapt to rough surface and paint detection, with coupling status prompt function.

$ 687.00

Measurement thickness up to 63.5 mm, accuracy of +/- 3%, measurement of magnetic and nonmagnetic metal substrates on nonconductive coatings, equipped with braided stainless steel cable anti-torsion wear.

$ 2002.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.