The three-box structure realizes independent temperature control in the high temperature and low temperature area, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, the air circuit switching Impact mode is adopted, and the microcomputer equilibrating temperature control system is equipped.
Adopt three-box structure to achieve rapid temperature conversion, conversion time ≤ 10 seconds, temperature control accuracy of +/- 0.5 ℃, equipped with air passage switching system and microcomputer equilibrate temperature control system to ensure test Stability.
The independent control structure of the cold and hot box is adopted, with a temperature conversion time of less than 15 seconds and a temperature recovery time of less than 5 minutes. It is equipped with multiple safety interlock protection and standard lead hole design to ensure efficient and safe testing.
The three-box structure is used to realize the static test sample, the heat storage and cold storage design is matched with the forced air circuit switching, the temperature conversion only takes 10 seconds, and the temperature control accuracy reaches +/- 0.5 ℃, which meets the requirements of continuous testing in extremely high temperature and extremely low temperature environment.
The three-box structure design is adopted, the test sample is still in the test area, the temperature recovery time is ≤ 5min, and the conversion time is ≤ 10s. It has three test functions of high temperature, low temperature and Thermal Shock, meeting a variety of standard requirements.
Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.
The three-box structure realizes independent temperature control in the high temperature zone, the low temperature zone and the test zone. The temperature conversion time is within 10 seconds, and the temperature control accuracy reaches +/- 0.5 ° C. The air circuit switching method is used for rapid Impact testing to improve the material testing efficiency.
With the independent control structure of the cold and hot box, the temperature conversion takes only 15 seconds and the recovery time does not exceed 5 minutes. The temperature fluctuation in the sample area is controlled within +/- 0.5 ° C, the load-bearing capacity is up to 40kg, and it is equipped with safety interlock protection and 7-inch Touchscreen controller.
Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -60~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, 304 stainless steel studio to ensure long-term stable operation.
Adopt three-box heat storage and cold storage structure, temperature conversion time ≤ 10 seconds, Temperature range -65 ℃~ + 150 ℃, with independent temperature control functions in high temperature zone, low temperature zone and test zone, and can perform 2-box or 3-box Impact mode.
Three-box structure design, temperature conversion time ≤ 10 seconds, temperature recovery time ≤ 5 minutes, equipped with High Accuracy microcomputer control system, can simulate extremely high temperature and extremely low temperature environment for static Impact testing of materials.
The three-box structure realizes the separation of the high temperature zone, the low temperature zone and the test zone, the air passage switching mode intRoduces the temperature for Impact, the temperature conversion time is ≤ 10 seconds, the temperature control accuracy is +/- 0.5 ℃, and the microcomputer equilibrate temperature control system and the double-stage Compressor chill down.
Temperature range -20~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision stable temperature control, to meet a variety of standard test requirements.
Three-box structure design, temperature conversion time does not exceed 10 seconds, temperature control accuracy of +/- 0.5 ℃, liner size 800 * 850 * 600mm, suitable for material thermal expansion and contraction test, easy to operate.
The Three-Box structure is used to distinguish the high temperature zone, the low temperature zone and the test zone, and the air passage is switched to achieve temperature impact. The maximum cycle period is 9999 times, and the Temperature range is -60~ 150 ° C. It supports automatic cycle or manual selective impact.