Digital Flame PhotoMeter

The flame photometer determines the concentration of elements by exciting them in a flame to produce characteristic spectra and measuring the intensity of light at specific wavelengths. It is used to detect the content of alkali metals, alkaline earth metals, and other elements, and is widely applied in fields such as chemical engineering, environmental protection, and food for rapid analysis.
Selection
When selecting a flame photometer, consider the types of elements to be detected and sensitivity requirements, compatibility of flame type with sample characteristics, ease of operation and maintenance, alignment of data output methods with laboratory needs, and balancing budget with long-term operational costs.

Terms

Standards

Instruments

Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.

$ 820.00

Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.

$ 1493.00

Dual channel LED digital display ensures clear reading, using silicon Photocell, photovoltaic cell detection to make the measurement results accurate and stable, Response Time is less than 8 seconds and has flameout protection function, safe and reliable operation.

$ 1332.00

Dual channel LED digital display, using silicon Photocell, photovoltaic cell detection, measurement Repeatability relative standard deviation ≤ 2%, can simultaneously detect various elements of potassium, sodium, lithium, calcium and barium, the sample amount is small and Sensitivity is high.

$ 1493.00

Dual channel LED digital display, button type automatic ignition design, using silicon Photocell, photovoltaic cell to ensure accurate and stable measurement, Measurement range 0.0-10 mmol/L, Measurement range 0.0-200 mmol/L, Sensitivity high and with flameout protection function.

$ 1493.00

Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.

$ 946.00

Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium function expansion, silicon Photocell, photovoltaic cell detection accuracy is high, Linearity ≤ 0.07, detection limit is as low as 0.004mmol/L, sample volume is small Sensitivity is high, flameout protection is safe and reliable.

$ 1493.00

Dual-channel LED digital display, Silicon Photocell, photovoltaic cell detection to ensure accurate and stable, potassium, sodium, lithium, calcium and barium multi-element simultaneous detection, Sensitivity is high and the sample amount is small, Linearity ≤ 0.07.

$ 1493.00

Dual channel LED digital display, potassium and sodium can be detected at the same time, lithium calcium detection function, silicon Photocell, photovoltaic cell detection is accurate and stable, the sample amount is small and Sensitivity is high, Linearity ≤ 0.005, detection limit ≤ 0.004.

$ 1493.00

Dual channel LED digital display, potassium and sodium detection and have lithium calcium function, using silicon Photocell, photovoltaic cell to ensure measurement Stability, small sample Sensitivity, with flameout protection safety design.

$ 2042.00

Dual-channel LED digital display clear reading, button automatic ignition fast and reliable, can simultaneously detect potassium and sodium and support lithium calcium barium measurement, using silicon Photocell, photovoltaic cell detection accuracy, small sample Sensitivity, with flameout protection safety function.

$ 1493.00

Dual channel design can simultaneously detect potassium and sodium elements, detection limit potassium ≤ 0.004mmol/L, sodium ≤ 0.008mmol/L, with automatic calculation of correlation coefficient and flameout protection function, Response Time is less than 8 seconds.

$ 1185.00

Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, Response Time is less than 8 seconds, support lithium calcium detection function.

$ 904.00

Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium can be detected at the same time and have lithium calcium detection function, small sample Sensitivity, Response Time is less than 8 seconds, with flameout protection function safe and reliable.

$ 677.00

Silicon Photocell, photovoltaic cell detection to ensure accurate and stable measurement, potassium and sodium detection limit of 0.004mmol/L and 0.008mmol/L, support lithium calcium detection function, small sample and Sensitivity.

$ 961.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
Key Technical Points for Determining Arsenic and Mercury in Water Using Atomic Fluorescence Spectrophotometry
This article introduces the key techniques for determining arsenic and mercury in water using an atomic fluorescence spectrometer. The experiment requires attention to safety precautions, regular maintenance of the instrument, and proper disposal of waste liquids.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.