Frequency flaw Detector

The frequency flaw detector emits high-frequency sound waves into the interior of materials. When encountering defects, the reflected sound waves are received and analyzed. It is used to detect internal cracks, pores, and other flaws in materials, and is commonly applied in quality inspections of metal components and welded joints.
Selection
When selecting, consider matching the detection material thickness and type with the frequency range, determine the resolution based on defect size, ensure environmental adaptability involves the protection rating, require the operation interface to be simple and easy to read, and ensure probe compatibility covers common testing scenarios.

Terms

Standards

Instruments

With ten independent flaw detection channels, the gain range is 120dB, the frequency band is 0.4~ 20.0MHz, and it supports automatic generation of DAC Linear dispersion and 500 data storage for efficient defect identification.

$ 1897.00

With DAC Linear dispersion automatic generation function, transmission Frequency up to 1000Hz, support 6 Meters detection range and 10 independent flaw detection channels, real-time dynamic video recording and automatic measurement crazing depth.

$ 2139.00

With 16 flaw detection channels and 0.5~ 20MHz Frequency range, it supports Automatic calibration probes and generates DAC Linear dispersion. High Sampling rate and low noise design meet a variety of operating conditions inspection needs.

$ 1172.00

With a wide frequency range of 64Hz-2MHz, it can detect longitudinal crazing and transverse defects, adapts to a variety of Probe types, supports automatic phase analysis and zero correction functions, and is suitable for high-speed inspection environments.

$ 7335.00

Using 64Hz-2MHz broadband range, it can detect vertical crazing and horizontal defects, with automatic zero correction system and sound and light alarm function, and supports a variety of Probe adaptations.

$ 10401.00

Frequency range 50Hz~ 12MHz, gain 0~ 90dB continuously adjustable, with relatively independent test channels and a variety of Display modes.

$ 8949.00

With 130dB high gain and Automatic calibration function, support 100 independent flaw detection channels and 1000 waveform storage, Scanning range 0-10000mm, to meet the needs of a variety of material flaw detection.

$ 1587.00

With 15 independent flaw detection channels and Automatic calibration function, the near-field blind area is small to meet the thin-walled tube detection, the working Frequency is 0.4MHz~ 15MHz, the Continuous Operating Time is more than 8 hours, and the waterproof, oil-proof and dust-proof design is supported.

$ 1640.00

With 100 flaw detection channels and 300 graphics storage capacity, support three probe modes and automatically generate DAC Linear dispersion, waterproof and dustproof design to adapt to harsh environments, Operating temperature range -27~ 70 ℃.

$ 2946.00

Scanning range 0-10000mm, working time 8 hours, waterproof and dustproof function, support 100 flaw detection channels and three probe modes, can automatically generate DAC Linear dispersion and store 300 inspection data.

$ 2623.00

Scanning range 0-6000mm, 100 independent flaw detection channels, support Automatic calibration and defect echo positioning, with high-brightness color display and three-proof design, adapt to various complex working environments.

$ 1816.00

Detection range 0-1000mm, dynamic range is greater than 36dB, with Automatic calibration and gate alarm function, support for a variety of working modes of straight oblique probes, compact and portable for field operations.

$ 3268.00

Scanning range 0-10000mm, working time 8 hours, waterproof and dustproof function, support 100 flaw detection channels and three probe modes, can automatically generate DAC Linear dispersion and store 300 A-shaped graphics.

$ 3268.00

Equipped with 10 independent flaw detection channels and 110dB gain range, supports DAC Linear dispersion automatic generation and 500 data storage, adopts 5.5-inch EL flat screen display, weighs only 1.6kg and is easy to carry, and can work in -20 ℃~ 50 ℃ environment.

$ 4027.00

Using the equilibrate recognition mode and 7.2kHz Detection Frequency, it can distinguish ferrous metals, with a detection depth of 1.8 Meters, LED lights and sound prompts, Sensitivity can be adjusted.

$ 141.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Resistance meter selection testing frequency and material conductivity range
This article primarily discusses how to consider test frequency and material conductivity range when selecting a resistivity meter.
MIT Folding Endurance Tester is used for high-frequency folding tests.
This article introduces the application of the MIT folding endurance tester in high-frequency folding tests. High-frequency folding tests simulate the actual usage of materials under rapid and repeated folding, placing high demands on the instrument, requiring it to possess high frequency, high precision, and stability.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
Selection Differences Between Random Vibration and Sine Vibration Tests
This article primarily discusses the differences between random vibration and sinusoidal vibration tests. Sinusoidal vibration uses a periodic signal at a single frequency, making it suitable for identifying resonance points and conducting fatigue tests. Random vibration, on the other hand, employs a broadband random signal to simulate real-world environments, such as transportation jolts, making it more appropriate for reliability acceptance testing.
Paper smoothness and roughness
Paper smoothness and roughness are key parameters that describe the flatness of the paper surface, and they complement each other. Smoothness refers to the extent to which the paper surface approaches an ideal plane, while roughness reflects the amplitude and frequency of surface irregularities.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
To determine if an ultrasonic cleaner cleans effectively, first understand the two key parameters: frequency and power.
This article mainly discusses how to achieve thorough cleaning with an ultrasonic cleaner, emphasizing that the key factors are frequency and power. The frequency determines the size and penetrating ability of the bubbles generated during cleaning, while the power provides the necessary energy for the cleaning process.