Rapid Temperature Change Humidity Test Chamber

The rapid temperature and humidity test chamber simulates fast temperature and humidity cycling environments inside the chamber through its refrigeration and heating systems and humidification device. It is used to detect the performance changes of materials under drastic temperature and humidity variations, commonly applied in weathering tests for products in industries such as electronics and coatings.
Selection
Focus on the temperature change rate range, humidity control accuracy, and the compatibility between chamber volume and sample dimensions during selection. Verify whether the compressor power and heater configuration meet the requirements for heating and cooling, and confirm the response speed and uniformity indicators of the humidity sensor. Consider the corrosion resistance of the chamber material and the convenience of daily maintenance.

Terms

Standards

Instruments

Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.

$ 13064.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure Temperature Uniformity ≤ 2 ° C, with remote monitoring function.

$ 28119.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.

$ 25973.00

Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.

$ 9836.00

Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve rapid temperature change of 5 ° C/min; equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, support 120 groups of program editing and remote monitoring functions.

$ 20599.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and is equipped with a two-stage throttling system and a forced air duct to ensure temperature uniformity ≤ 2 ° C. Remote visual control and fault self-diagnosis functions are supported through RS485 communication.

$ 20599.00

Using multi-channel mechanical compression refrigeration system and frequency conversion technology, energy consumption is reduced by 20%; with a linear temperature rise and fall rate of 15 ° C/min, Temperature Uniformity ≤ 2 ° C; through forced air duct system and special PID algorithm to achieve rapid temperature convergence and stability control.

$ 15210.00

With a linear temperature rise and fall rate of 10 ° C/min and a wide temperature range of -60 to 150 ° C, multi-channel refrigeration system and PID adaptive algorithm are used to achieve rapid temperature convergence, and environmentally friendly refrigerants and low noise design are equipped.

$ 18437.00

Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, reduce energy consumption and noise through frequency conversion technology, and support 120 sets of program editing and remote monitoring functions.

$ 28119.00

Multi-channel mechanical compression refrigeration system and adaptive throttling technology are used to achieve 5 ° C/min linear temperature rise and drop and +/- 0.5 ° C Temperature Fluctuation; equipped with PID adaptive algorithm and forced air duct system to ensure temperature uniformity and rapid convergence.

$ 15210.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., with 100 program capacity and rapid temperature change performance, suitable for harsh environment testing.

$ 9755.00

The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and the PID adaptive algorithm is equipped to ensure that the Temperature Uniformity is ≤ 2 ° C, and the 512L studio meets the diverse testing requirements.

$ 31347.00

Multi-channel mechanical compression refrigeration system and frequency conversion technology are used to achieve linear temperature rise and drop at 10 ° C/min, with Temperature Uniformity ≤ 2 ° C. Equipped with PID adaptive algorithm and remote visual control to improve test efficiency and Stability.

$ 23827.00

The multi-channel mechanical compression refrigeration system saves up to 20% energy, is equipped with a 512L studio and a rapid temperature change rate of 5 ° C/min, and guarantees temperature uniformity through a forced air duct system. It supports 120 sets of program capacity and remote visual control.

$ 13064.00

Using multi-channel mechanical compression refrigeration system, energy saving up to 80% of congeneric pRoducts; with 5 ℃/min rapid temperature change rate; through forced air duct system to ensure Temperature Uniformity ≤ 2 ℃; equipped with remote monitoring and fault self-diagnosis function.

$ 15210.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.