Measurement range covers 50~ 5600kPa, Precision up to +/- 0.5%, using all-steel chain drive and high voltage oil circuit sealing system to ensure test Stability and long life.
Adopt 24-bit High Accuracy AD converter and stable pressure sensor, Measurement range 50~ 1400kPa, with full scale alarm and 3-speed limit protection function, support a variety of Unit switches and thermal printouts.
Equipped with high light transmitance Glass liner, transmission Illumrination degree 1000Lux, reading Microscope magnification 100X, can accurately measure pinholing size and quantity.
Measurement range 50~ 1400kPa, accuracy error ≤ +/- 0.5%, fully enclosed hydraulic system to ensure high Stability, support a variety of unit conversion and thermal print output.
Using intelligent control pressure relief system, Measurement range 10~ 1600kPa, Indication Error ≤ +/- 0.5%, all-steel chain drive to improve Stability, real-time observation of test sample blasting process.
Measurement range 200~ 5600kPa, Precision ≤ +/- 0.5%, all-steel chain drive to improve Stability, three-dimensional semicircular window easy to observe the deformation process.
Using high-speed ARM processor and 32-bit High Accuracy AD converter, Measurement range 50~ 1400kPa, with over-range alarm and unplaced sample prompt function, support pressure and deformation Linear dispersion display, stable and reliable operation.
Measurement range 50~ 1600kPa, resolution 1kPa, oil feeding speed 95 +/- 5mL/min, with automatic test and sample rupture automatic stop function, support data calculation and printing report.
Using membrane button operation and LCD liquid crystal display, Measurement range 350~ 5500kPa, resolution 1kPa, with automatic test, automatic stop and automatic calculation of multiple sets of data average function.
The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the haze Repeatability is less than 0.1, and the open sample compartment supports vertical horizontal testing to adapt to multiple samples with thickness less than 170mm.
PD array Detector was used to satisfy CIE V (lambda) 2 degree Visual Response. High Accuracy light transmitance and haze data were measured by compensation method. Measurement time was about 1.5 seconds.
PD array Detector, to meet the CIE V (lambda) 2 degree Visual Response, compensation method measurement, haze Repeatability less than 0.05, open sample compartment to adapt to vertical or horizontal testing, dynamic monitoring of Illuminant and environment changes.
The PD array Detector and Φ 8mm measurement aperture are used to meet the CIE V (lambda) 2 degree visual Response, and the open sample compartment supports vertical horizontal testing. Measurement time is about 1.5 seconds, and the haze resolution is 0.01 units.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
PD array Detector to achieve CIE V (lambda) 2 degree Visual Response, measurement aperture Φ 15mm, support open sample Chamber vertical horizontal test, dynamic monitoring of Illuminant and environment changes to ensure reliable data.