Torque Calibrator

A torque calibrator measures the torque applied by rotating components through sensors and is used to verify and adjust the accuracy of torque tools. In manufacturing, maintenance, and quality control, it ensures that fasteners such as bolts and nuts achieve the specified torque, preventing over-tightening or under-tightening.
Selection
When selecting a torque calibrator, it is essential to consider that the measurement range covers the application requirements, the accuracy grade meets the standards, and environmental adaptability factors such as temperature effects are taken into account, along with calibration certificates and ease of use. Based on the actual types and frequency of torque tools, choose a suitable model to ensure long-term stability and cost-effectiveness.

Terms

Standards

Instruments

Frequency 159.2Hz, Acceleration output 14.14m/s ², Maximum load 150g, compact and portable, fast heating, low lateral output, suitable for rapid vibration detection system.

$ 598.00

Provides 94dB and 114dB dual sound pressure level output, Frequency accuracy 1000 + 0.1% Hz, supports Φ 12.7mm and Φ 23.77mm microphone calibrated, temperature coefficient 0~ 0.01dB/° C, Handheld design is easy to use on site.

$ 388.00

Equipped with 94dB and 114dB dual sound pressure level output, Frequency accuracy up to 1000 + 0.1% Hz, support a variety of Frequency weighting correction; Application specific integrated circuit to improve Stability, suitable for Φ 12.7mm and Φ 23.77mm microphones, Operating temperature range -10~ + 50 ° C.

$ 241.00

Frequency 159.2Hz, Acceleration output 10m/s ², Support 150g load verification, Transverse output less than 5%, Heating time less than 3 seconds, Compact handheld design for fast detection.

$ 703.00

Adopt 0.5% F.S. High Accuracy torque Sensor, support bi-directional torque test and 400 sets of Data storage, with locking force and opening force dual Measurement mode and peak hold function, to meet the needs of a variety of Encasement container testing.

$ 1106.00

Sampling speed up to 1920HZ, accuracy level 0.5, support three units of automatic conversion and a variety of test mode, with data storage and qualified judgment function, suitable for high-speed Impact torque detection.

$ 974.00

With 1 level accuracy and +/- 1% Indication Error, it supports three test modes of real-time torque tracking, peak holding and first peak, and can store 99 sets of data and automatically calculate statistical values.

$ 2026.00

Electronic Sensor technology implementation 0.5 level accuracy, support three torque units automatic conversion, with peak hold and real-time tracking mode, can store 99 sets of data and automatically calculate statistical values.

$ 696.00

DC brushless motor, Speed range 30-2200rpm, Max. Torque 60N.cm, can automatically adjust the torque to adapt to viscosity changes, with overload and abnormal automatic protection, support long-term continuous operation.

$ 743.00

DC brushless motor, Speed range 30-2200rpm, Max. Torque 80N.cm, can automatically adjust torque according to viscosity, support long-term continuous operation, with overload and abnormal automatic protection function.

$ 787.00

Speed range 30-2200rpm, Max. Torque 80N.cm, DC brushless motor to ensure long-term safe operation, with automatic torque adjustment and overload protection functions, equipped with a variety of Impeller to adapt to different viscosity requirements.

$ 795.00

DC brushless motor, Speed range 30-2200rpm, Max. Torque 60N.cm, can automatically adjust torque according to viscosity, with overload and abnormal automatic protection function, support long-term continuous operation.

$ 690.00

DC brushless motor, Speed range 30-2200rpm, Max. Torque 60N.cm, can automatically adjust the torque to adapt to viscosity changes, with overload and abnormal automatic protection, support long-term continuous operation.

$ 748.00

Speed range 30-2200rpm, Max. Torque 80N.cm, DC brushless motor can run for a long time, with automatic overload protection and torque automatic adjustment function, equipped with a variety of Impeller to adapt to different viscosity requirements.

$ 829.00

The device has +/- 0.5% high accuracy, the maximum clamping diaMeter is 200mm, supports three units automatic conversion and 99 sets of data storage, and is suitable for bottle cap opening and closing torque detection.

$ 791.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
The Working Principle and Calibration Method of Electronic Paper Tensile Strength Tester
The electronic paper tensile strength tester is used to measure the mechanical properties of materials such as paper under tension. It is recommended to calibrate the instrument annually and maintain a stable environment along with clean fixtures during daily use.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Key Operation Points of Carton Burst Strength Tester
The carton bursting strength tester is used to measure the maximum force that paperboard can withstand before rupturing under uniform pressure, which is important for packaging quality control. Before operation, ensure that the instrument is stable and the calibration is valid. The samples should be cut according to standards and conditioned under standard temperature and humidity conditions.
Standard Operating Procedure for Packaging Drop Tester
The packaging drop tester is used to evaluate the impact resistance of transport packages during vertical drops. Before operation, it is necessary to check the safety of the equipment, calibrate the drop height, and prepare the test specimens according to standards.
Key points for operating a hot melt adhesive softening point tester
The hot melt adhesive softening point tester is used to measure the softening temperature of materials when heated, which is important for quality control. Before operation, ensure that the ambient temperature is around 23 degrees, place the instrument level, check if the heating oil is clean, and calibrate the sensor.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.
Calibration and Use of Paper Whiteness Tester
This article introduces the working principle, calibration process, operational steps, and factors influencing the measurement results of a paper whiteness tester. The instrument evaluates whiteness by measuring the reflectance of blue light from paper, and calibration requires the use of a standard whiteboard in accordance with relevant standards.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.